GarrettCom Magnum 6K25 Hardware Installation And User's Manual page 63

Managed fiber switch
Table of Contents

Advertisement

Magnum 6K25 Managed Fiber Switch
Input Voltage:
Power Consumption: Same as for AC models (see Section 1.1)
Power Supply (Internal 24 VDC Option) Industrial Applications
DC Power Connector: 3 terminals: "
Input Voltage:
Power Consumption: Same as for AC models (see Section 1.1)
Power Supply (Internal 125 VDC Option) Industrial Applications
DC Power Connector: 3 terminals: "
Input Voltage:
Power Consumption: Same as for AC models (see Section 1.1)
With the exception of the power supply, all specifications and
functions of Magnum 6K25 Switch -48VDC, 24VDC and 125VDC models are
identical to those listed in the main manual.
B2.0
-48VDC, 24VDC and 125VDC POWER, THEORY OF OPERATION
The -48VDC, 24VDC and 125VDC power options are designed using diodes
inside on each DC power input line behind the two external power connection terminals,
so that the power from an external
source can only flow into the hub.
This allows the Switch to operate
only whenever DC power is
correctly applied to the two inputs.
It protects the Switch from incorrect DC input connections. An incorrect polarity
connection, for example, will neither affect the Switch, its internal power supply, nor will
it blow the fuse in the internal power supply.
The manual power "On-Off" Switch (optional) is used for powering the unit on
and off when it is placed into or taken out of service.
B3.0
APPLICATIONS FOR DC POWERED SWITCHES
Magnum 6K25 Fiber Switches are easily installed in a variety of applications
where -48VDC, 24VDC and 125VDC power is used as the primary power source. The-
48VDC, 24VDC and 125VDC power configuration provides an Ethernet networking
solution utilizing a special power supply in a managed Fiber Switch.
The –48VDC solution is particularly useful in the telecommunication industry,
where it is common for facilities to operate on -48VDC power. Such companies include
regular and wireless telephone service providers, Internet Service Providers (ISPs) and
other communication companies. In addition, many high availability equipment services,
such as broadcasters, publishers, newspaper operations, brokerage firms and other
facilities often use a battery backup system to maintain operations in the event of a power
failure. It is also frequently used for computer system backup, management and
operations monitoring equipment.
www GarrettCom com
.
.
Installation and User Guide (04/06)
36 - 70 VDC
-
20 - 36 VDC
-
88 - 150 VDC
A+
A-
GND
56
", "GND", "+"
", "GND", "+"
POWER SWITCH
SUPPLY
HUB
+
FUSE
-
CHASSIS
GND