Dell Latitude C600 User Manual page 130

Hide thumbs Also See for Latitude C600:
Table of Contents

Advertisement

drive
No timer tick
interrupt
Non-system
disk or disk
error
Not a boot
diskette
Optional ROM
bad checksum
Sector not
found
Seek error
Shutdown
failure
Time-of-day
clock lost
power
Time-of-day
clock stopped
Time-of-day
not set-
please run
the System
Setup program
Timer chip
counter 2
failed
Unexpected
interrupt in
protected
mode
A chip on the system board may
be malfunctioning.
The diskette in drive A or your
hard-disk drive does not have a
bootable operating system
installed on it.
There is no operating system on
the diskette.
The optional ROM apparently
failed.
The operating system cannot
locate a sector on the diskette or
hard-disk drive. You probably
have a bad sector or corrupted
FAT on the diskette or hard-disk
drive.
The operating system cannot find
a specific track on the diskette or
hard-disk drive.
A chip on the system board may
be malfunctioning.
Data stored in NVRAM has
become corrupted.
The reserve battery that supports
the data stored in NVRAM may
be read.
The time or date stored in the
system setup program does not
watch the system clock.
A chip on the system board may
be malfunctioning.
The keyboard controller may be
malfunctioning, or an installed
memory module may be loose.
Run the System Set tests in the
Diagnostics.
If you are trying to boot from the diskette, replace
it with one that has a bootable operating system.
Boot the computer with a diskette that contains an
operating system.
Call Dell
for technical assistance.
Run the appropriate utility to check the file
structure on the diskette or hard-disk drive. If a
large number of sectors are defective, back up the
data (if possible), and then reformat the diskette
or hard-disk drive.
If the error is on the diskette drive, try another
diskette in the drive.
Run the System Set tests in the
Diagnostics.
Connect your computer to an electrical outlet to
charge the battery. If the problem persists, try to
restore the data. To restore the data, press
<Fn><F1> to
enter the system setup
Then immediately exit it. If the message
reappears,
call Dell
for technical assistance.
Connect your computer to an electrical outlet to
charge the battery. If the problem persists,
Dell
for technical assistance.
Correct the settings for the Date and Time
options. (For instructions, see
Program.")
Run the System Set tests in the
Diagnostics.
Run the System Memory tests and the
Keyboard Controller test in the
Diagnostics.
Dell
Dell
program.
call
"System Setup
Dell
Dell

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Latitude c500

Table of Contents