Compaq AlphaServer 160 User Manual page 99

Alphaserver gs80; alphaserver 160; alphaserver 320
Table of Contents

Advertisement

6.2.5
ei*0_protocols or ew*0_protocols
The ei*0_protocols or ew*0_protocols environment variable sets
network protocols for booting and other functions.
To list the network devices on your system, enter the show device command.
The Ethernet controllers start with the letters "ei" or "ew," for example, eia0.
The third letter is the adapter ID for the specific Ethernet controller. Replace
the asterisk (*) with the adapter ID letter when entering the command.
The syntax is:
set ei*0_protocols protocol_value or
set ew*0_protocols protocol_value
The options for protocol_value are:
mop (default)
bootp
bootp,mop
Example
P00>>> show device
.
.
.
eia0.0.0.1001.0
eib0.0.0.12.0
eic0.0.0.13.0
.
.
.
P00>>> set eia0_protocols bootp
P00>>> show eia0_protocols
eia0_protocols
Sets the network protocol to mop (Maintenance Operations
Protocol), the setting typically used with the OpenVMS
operating system.
Sets the network protocol to bootp, the setting typically used
with the Tru64 UNIX operating system.
When both are listed, the system attempts to use the mop
protocol first, regardless of which is listed first. If not
successful, it then attempts the bootp protocol.
EIA0
EIB0
EIC0
bootp
Booting and Installing an Operating System
08-00-2B-3E-BC-B5
00-00-C0-33-E0-0D
08-00-2B-E6-4B-F3
6-15