Example 6–1 SCM Power-Up Display (Continued)
I~ HSW4/HPM40 SysEvent: LINK1_ON
SCM_E0>
I~ HSW4/HPM40 SysEvent: LINK2_ON
SCM_E0>
I~ HSW4/HPM40 SysEvent: LINK3_ON
SCM_E0>
.............................................................................
.........................................................................
SCM_E0> ......................................
The user issues a power on command.
Messages denoted by ~I~ are informational and do not indicate a serious
event. Other types of messages include:
*** – Diagnostic format indicating an error has occurred.
### – Diagnostic format indicating a warning.
~E~ – An error has occurred; power-up continues, but the affected resource
is dropped.
~W~ – An error has occurred; power-up continues, and the affected
resource is questionable.
During the Phase INIT (initialization phase) SROM code is loaded into
each CPU in the system and communication between the power system
manager (PSM) and the CPU is established. Phase 0 follows with local
QBB testing.
Booting and Installing an Operating System
Reg0:010F Reg1:AB81
Reg0:030F Reg1:AB81
Reg0:070F Reg1:AB81
Continued on next page
6-3