8.7.6
Configuring Alert Dial-Out
Set a few parameters to configure alert dial-out. The dial string and
alert string are set to send a message to a remote operator. When an
alert condition is triggered, the dial string is sent first, followed by the
alert string. Once the two strings are set, alert dial-out is enabled and
the new parameters should be verified. The elements of the dial string
and alert string are shown in Table 8–3.
You must configure remote dial-in for the dial-out feature to be enabled.
To set up the dial-out alert feature, enter the SCM from the local console device.
Example 8–2 Alert Dial-Out Configuration
SCM_E0> set dial atdt915551212
SCM_E0> set alert ,,,,5085551234#;
SCM_E0> enable alert
Enabling alerts
SCM_E0> test alert
SCM_E0> show status
System Management Settings
RMC escape sequence
Local BAUD/flow control
COM1 BAUD/flow control
Modem BAUD/flow control
COM1 Mode
OCP power switch
OCP HALT
OCP secure
Remote access
Remote user
Alerts
Modem password
Modem init string
Modem dial string
Modem alert string
Alert pending
Most recent alert
SCM_E0> clear alert
Pending alert cleared
SCM_E0>
8-26
AlphaServer GS80/160/320 User's Guide
:
<Esc><Esc>scm
:
57600 / soft
:
57600 / hard
:
57600 / hard
:
Pass-through
:
Off
:
Deasserted
:
Non-Secure
:
Enabled
:
Not Connected
Enabled
:
wffirmware
:
ate0v0&c1s0=2
:
atdt915551212
:
,,,,5085551234#;
:
YES
:
User initiated ... from CSB node e0