Server system
Table of Contents

Advertisement

System expansions
LED
HDD BUSY
green
– lights: drive active
– does not light: drive inactive
LED
HDD FAULT (in conjunction with a disk array controller)
orange
– does not light: No HDD Error
– lights: HDD Faulty or Rebuild Stopped (drive defective/needs
replacing), a rebuild process was stopped or the slide-in module is
not correctly inserted
– slow blink: HDD Rebuild (a rebuild is carried out by the DAC after
changing a hard disk drive
– fast blink: HDD Identify
– four fast blinks/pause: HDD Predicted Fault
– two fast blinks/pause: HDD Hot Spare (Hot spare drive active. The
corresponding drive has failed.
Table 24: SCSI disk drives status control
8.2.1

Replacing SCSI hard disk drives

V
CAUTION!
Never pull out a hard disk drive during operation if you are not sure that
the hard disk drive is operated on a RAID controller and is part of a disk
array that operated in the mode RAID Level 1or 5.
A defective drive as part in a disk array has to be replaced during
operation only.
The hard disk drives which can be ordered for the server are supplied already
mounted in the hard disk drive slide-in modules. A hard disk in the hard disk
drive slide-in module can only be replaced by a service technician.
If you want to swap a SCSI hard disk drives during operation, proceed as
follows:
If you wish to insert a hard disk drive in an empty bay, then the dummy module
must be removed from this bay beforehand.
Installing/removing the dummy module is performed in the same manner of the
hard disk drives.