PT-60LCX64-K
SERVICE POSITION (3)
FULL MIRROR ADJUSTMENT & POLARIZER ADJUSTMENT OF PROJECTION UNIT
It is possible to adjust the Full Mirror and Polarizer of Projection Unit.
The following service tools are required:
LCD Panel Flat Extension Cable (LSUA0042) X3
Relay P.C.B. (LSEP3112A) X3
Fan1,3 Extension Cable (LSUA0039) X2
Fan2 Extension Cable (LSUA0040)
Signal Extension Cable (LSUA0037)
Power Extension Cable (LSUA0038)
Thermistor 1 Defeat Cable (LSUA0003)
Thermistor 2 Defeat Cable (LSUA0013)
Cover Switch Defeat Cable (LSUA0041)
Note:
Connections are the same as Fig. S2-4
(However, the RS232C I/F Tool is not used in this service position)
The following original parts are not connected:
Thermistor 1 C.B.A.
Thermistor 2 C.B.A.
20-pin Cable
Cover Switch C.B.A.
Cabinet
D-Sub 15 Pin
RGB Cable
Video
Input 1
Terminal
AC Cord
Operation
C.B.A.
The following equipment is required:
File, etc.
PC (2) for Test
Pattern Signal
TV/Tuner Unit
RGB Input
1 Terminal
Signal
Extension
Cable
Screen
PC (2) for Test Pattern Signal
D-Sub 15 Pin RGB Cable (for connecting the PC Input Terminal)
For more details, See Fig. S3-2.
Relay P.C.B.s
For more details, See Fig. S2-7.
Fig. S3-1
40
Projection Unit
LCD Panel Flat
Extension Cables
Ballast C.B.A.
For more details,
LCD Drive
See Fig. S2-8,
C.B.A.
S2-9, S2-10.
Power Extension
Cable