Pressure Transducer At Maximum Adjustment; Pressure Transducer Error - Count Too High; 103. Slave Display Comms Time Out See Fault Code 105; 104. See Fault Code 105 - Fisher & Paykel CleanSmart WL8060P1 Service Diagnostic Manual

Top load washing machine
Table of Contents

Advertisement

58. Pressure Transducer at Maximum Adjustment

When the pause or delay start is pressed to start the SmartDrive™, the Display Module has checked
the memory and found the count greater than expected.
Primary Source: Motor Control Module.
Action:
Replace Motor Control Module
68. Pressure Transducer Error – Count Too High
The pressure transducer has measured a water level far above what the machine should physically
be able to measure. This suggests that the pressure sensor has been disconnected from the motor
controller, damaged or not actually placed on the PCB.
Primary Source: Motor Control Module.
Action:
Replace Motor Control Module.

103. Slave Display Comms Time out see fault code 105

104. See Fault Code 105

105. Comms Error Time Out

These faults are reported when the Display Module detects an error in the communications
between the Display Module and the Motor Control Module. Can also occur when the display is
changed with the power still on.
Primary Source: Display Module.
Action:
Replace Display Module.
Secondary Source: Motor Control Module.
Action:
Replace Motor Control Module.

107. Motor Control Module Reset Error

The Display Module has detected that the Motor Control Module has reset when it should not have.
This can be due to a Motor Control Module supply disturbance or microprocessor failure.
Primary Source: Motor Control Module.
Action:
Replace Motor Control Module.
108. Comms CRC Error – See Code 105

112. Motor Current Sense Too High

The motor current sense circuit is faulty.
Primary source: Motor Control Module.
Action:
Replace Motor Control Module.