Dimensions and Weight
Table 15 Rack- or Pedestal-Mounted Server Dimensions
Data Center Server Dimensions
Depth
Width
Height
Data Center Server Weight
Rack unit
Office Friendly Server Dimensions
Depth
Width
Height
Office Friendly Server Weight
Grounding
The site building shall provide a safety ground/protective earth for each AC service entrance to
all cabinets.
Install a PE (protective earthing) conductor that is identical in size, insulation material, and thickness
to the branch-circuit supply conductors. The PE conductor must be green with yellow stripes. The
earthing conductor is to be connected from the unit to the building installation earth or, if supplied
by a separately derived system, at the supply transformer or motor-generator set grounding point.
Electrical Specifications
This section provides electrical specifications for the server.
System Power Specifications
Available power (output) is the maximum DC power that the power supply can supply to the system.
Maximum input power is what the power supply requires from the AC line to deliver that maximum
DC output (given worst case efficiency and maximum loading).
Maximum input current is the worst case/highest current given the lowest input voltage and the
maximum input power.
Table 16 System Power Specifications
Input voltage
Marked input current
Input current (maximum)
Input frequency
36
Server Specifications
Dimensions and Weight
Parameter
67.3 cm (26.5 in)
48.3 cm (19 in)
8.6 cm (3.4 in)
Minimum configuration – 21 kg (46 lb)
Maximum configuration – 28 kg (61 lb)
2U
69.0 cm (27.18 in)
27.6 cm (10.88 in) w/feet
12.7 cm (5 in) w/o feet
50.8 cm (20 in)
Minimum configuration – 30 kg (66 lb)
Maximum configuration – 37 kg (81 lb)
100 VAC
100- 1 27 VAC
10 A
10 A
10 A
10 A
47 to 63 Hz
47 to 63 Hz
Value
Total Rating
200-240 VAC
7 A
6.7 A
47 to 63 Hz