To change the server from a rack mount to a rackless configuration, you need a Server Rackless
Mount Kit. The rackless mount kit comes with the HP Integrity rx2660 Server Pedestal Installation
Guide. Follow the steps in this installation guide to attach the pedestal to the server.

Connecting the Cables

This section describes the cables to connect to power the server and to provide LAN connectivity
for the server.

AC Input Power

The server can receive AC input from two different AC power sources. The power receptacles are
located at the rear of the chassis. They are labeled Power Supply 1 and Power Supply 2.
For the Data Center server, you can install a maximum of two power supplies in the server. Installing
two power supplies in the server provides 1+1 redundancy, meaning that if one power supply
fails, there is still enough power supplied to the server to operate. You must promptly replace the
failed power supply to restore 1+1 functionality.
A minimum of one power supply is required to power the server. If only one power supply is
installed in the server, there is no 1+1 capability.
For the Office Friendly server, two power supplies are required to power the server. The office
friendly server can run on one power supply, but runs quieter and more efficiently with two power
supplies installed.

Power States

The server has three power states:
Standby power
Full power
Off
Table 24 Server Power States
Power States
Standby power
Full power
Off
Power Cable
Power Activated through the iLO 2 MP PC
Plugged Into
Command; or Front Panel Power Button
Receptacle?
Activated?
Yes
No
Yes
Yes
No
No
Standby DC
DC Voltage
Voltage
Applied?
Applied?
Yes
No
Yes
Yes
No
No
Connecting the Cables
63