Cleaning/descaling and sanitizing
Periodic cleaning/descaling and sanitizing of Follett's ice and water dispenser and ice machine system is required
to ensure peak performance and delivery of clean, sanitary ice. The recommended cleaning procedures that follow
should be performed at least as frequently as recommended and more often if environmental conditions dictate.
Cleaning of the condenser can usually be performed by facility personnel. Cleaning/descaling and sanitizing of
the ice machine system should be performed by your facility's trained maintenance staff or a Follett authorized
service agent. Regardless of who performs the cleaning, it is the operator's responsibility to see that this cleaning is
performed according to the schedule below. Service problems resulting from lack of preventive maintenance will not
be covered under the Follett warranty.
Recommended cleaning/descaling and sanitizing intervals*
Symphony
Drain Line
Drain Pan/Drip Pan
Exterior
Condenser
Dispenser and Components
Ice Machine
Transport Tube
Ice Storage Area/Bin
* Ice machine and dispenser must be cleaned and sanitized prior to start-up.
Weekly
§ Do not use solvents, abrasive cleaners, metal scrapers or sharp objects to clean any part of the dispenser.
Dispenser drain pan and drain line
1. Pour 1 gal. (3.8 L) of hot tap water into drain pan to fl ush drains.
Splash panel front, SensorSAFE infrared dispensing
1. Deactivate dispensing by pressing and releasing clean switch located on left side of unit under top front
cover.
2. Clean lens and splash panel front using a soft cloth and mild, non-abrasive, non-chlorine based cleaner.
3. Reactivate dispensing by pressing and releasing clean switch again.
Monthly
§ Do not use solvents, abrasive cleaners, metal scrapers or sharp objects to clean any part of the dispenser.
Condenser (air-cooled ice machine only)
1. Use a vacuum cleaner or stiff brush to carefully clean condenser coils of lint and debris to ensure optimal
performance.
12CI400A • 12HI400A 220 V 60 Hz/230 V 50 Hz Dispensers
Frequency
weekly
weekly
as needed
monthly (air-cooled only)
semi-annually
semi-annually
semi-annually
semi-annually
CAUTION!
CAUTION!
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

12ci400a-l12ci400a-s12hi400a-s

Table of Contents