Cleaning and Sanitizing Procedure
Cleaning and sanitizing should be performed at least every 6 months (more often
if local water conditions dictate) .
Follett recommends cleaning/sanitizing the chiller/carbonator on a regular basis
using P/N 01147545 .
WARNING!
§ Place the dispenser in Maintenance Mode prior to servicing or
cleaning the ice machine. See
page
19.
§ For protection, rubber gloves and safety goggles (and/or face shield)
should be worn when handling SafeCLEAN Plus™.
§ Do not use bleach, it will damage the dispenser.
Required Supplies
§ 7 Series: 24 oz . (0 .71 L) of SafeCLEAN Plus liquid
15 Series: 48 oz . (1 .42 L) of SafeCLEAN Plus liquid
§ Funnel and Bucket
Ice machine and Dispenser
1 . Dispense all the ice out of the unit .
2 . Press and hold maintenance/clean switch until
interface to enter Maintenance Mode .
3 . Remove (unscrew) chrome ice dispense chute (Fig . 15 .1) .
4 . Remove drip tray (Fig . 15 .2) .
5 . Remove (2) screws located behind the drip tray (Fig . 15 .3) .
6 . Move front panel and place on top or beside unit (Fig . 15 .4) .
7 .
Remove plug cap from the end of drain tube (Fig . 15 .5) and lower tube
to drain water into bucket . After the system has been drained of water
replace plug cap in drain tube .
8 . Secure tube in holder .
9 . Remove cap from bin lid cover (Fig . 15 .6) .
10 . Screw bin lid cover cap onto ice discharge chute (Fig . 15 .7) .
11 . 7 Series: Mix 24 oz . (0 .71 L) of SafeCLEAN Plus liquid with three gallons (11 .4 L) of water .
15 Series: Mix 48 oz . (1 .42 L) of SafeCLEAN Plus liquid with six gallons (22 .7 L) of water .
12 . Pour SafeCLEAN Plus solution into bin lid access spout until solution reaches the spout neck .
13 . Allow the SafeCLEAN Plus solution to remain in unit for 15 minutes .
14 . While machine is cleaning, remove top and right side panel to access and clean air-cooled condenser .
15 . Submerge ice dispense chute in the remainder of SafeCLEAN Plus solution for 2 minutes . Rinse with
clean, potable water .
16 . Drain system by lowering drain tube into bucket .
17 . Secure drain tube into holder .
18 . Fill and drain twice with potable water . Secure drain tube .
19 . Place a bucket under the dispense chute and remove cap . Note: Some SafeCLEAN Plus solution will
remain and drain out when cap is removed . Reposition cap on bin lid spout .
20 . Reinstall front panel, ice dispense chute, and drip tray .
21 . Press and hold maintenance/clean switch to exit Maintenance Mode .
Maintenance/Cleaning Mode on
Sparkling Water and Ice Dispenser 7CI100A/7FS100A, 15CI100A/15FS100A
displays in the user
Fig . 15
1
3
2
4
6
7
5
21