Specifi Cations - Follett 12 Installation, Operation And Service Manual

12 series - 220 v 60 hz/230 v 50 hz ice and water dispensers
Table of Contents

Advertisement

Specifi cations

407 mm
(16")
Front View
Electrical
220 V 60 Hz, 1 phase, 6.5A
230 V 50 Hz, 1 phase, 6.5A
Furnished with 1.8m (6 ft) power cord.
Ambient
Air temp
Water temp
Water pressure
Plumbing
Dispenser drain
Water inlet
Note: Water shut-off recommended within 3m (10 ft) of dispenser. Drain to be hard-piped and insulated. Maintain
at least 20mm per 1m run (1/4" per foot) of slope.
Ventilation clearances
6" (153mm) on right side of dispenser, 6" (153mm) at top for ventilation and 12" (305mm) at top recommended for
service.
Note: Do not block right side air intake or top air exhaust.
Dry weight
79.4kg (175 lbs)
4
575 mm
(22.625")
102 mm
(4")
597 mm
(23.5")
Side View
38 C/100 F Max.
32 C/90 F Max.
5Bar Max./70 P.S.I.
826 mm
(32")
458 mm
(18")
10 C/50 F Min. (Best performance below 27 C/80 F)
4 C/40 F Min. (Best performance below 21 C/70 F)
0.7 Bar/10 P.S.I. Min.
C/E12CI400A
3/4" FPT
3/8" FPT
12CI400A • 12HI400A 220 V 60 Hz/230 V 50 Hz Dispensers
air exhaust
3/4" FPT drain
3/8" FPT
water inlet
air
intake
power cord
Rear View
C/E12HI400A
3/4" FPT
3/8" FPT

Advertisement

Table of Contents
loading

This manual is also suitable for:

12ci400a-l12ci400a-s12hi400a-s

Table of Contents