Thermostat and ice transport tube replacement
77mm
(3")
capillary
51mm
tube
(2")
bracket
hand bend cap tube end as shown
Ice transport tube replacement
1. Push tube onto evaporator port.
2. Position clamp behind lip on evaporator port and tighten clamp.
32
13mm
(.50")
TYP
Thermostat:
.25
Top View
12CI400A • 12HI400A 220 V 60 Hz/230 V 50 Hz Dispensers
ice tube retainer
ice tube
gasket
Ice transport
tube: tube may extend
a maximum of 7mm
(1/4") into ice bin