GarrettCom Magnum CSG14 Series Installation And User Manual

GarrettCom Magnum CSG14 Series Installation And User Manual

Gigabit converter switches
Hide thumbs Also See for Magnum CSG14 Series:

Advertisement

Magnum CSG14 Gigabit Converter Switches
Installation and User Guide
www GarrettCom com
.
.

Advertisement

Table of Contents
loading

Summary of Contents for GarrettCom Magnum CSG14 Series

  • Page 1 Magnum CSG14 Gigabit Converter Switches Installation and User Guide www GarrettCom com...
  • Page 2 Part #: 84-00102Z Rev. A Trademarks GarrettCom, Magnum, Link-Loss-Learn, S-Ring, Convenient Switch, Converter Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc. Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies...
  • Page 3 Magnum CSG14 10/100/1000 Mb/s Converter Switch products, consult Section 5, Troubleshooting, of this User Guide. Copyright © 2008 GarrettCom, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from GarrettCom, Inc.
  • Page 4 Operation of this equipment in a residential area is likely to cause interference, in which case the user, at his/her own expense, will be required to take whatever measures may be required to correct the interference. www GarrettCom com...
  • Page 5 CSG14 Series Gigabit Converter Switch Installation and User Guide (05/08) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Drive Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com...
  • Page 6: Table Of Contents

    Locating the Converter Switch Unit ..........37 MC14-TRAY for Rack Mounting of CSG14 Series Switches ..39 MC14-TR+PS9 and X2 for Rack Mounting Media Converters ..40 DIN-Rail mounting option ..............42 Power Requirements, CSG14 Series Switches ........43 www GarrettCom com...
  • Page 7 Triple-Speed Functionality, and Switching ........56 Auto-cross (MDIX), Auto-negotiation and Speed-sensing ....58 Dual LEDs, Front-panel and Side-panel ..........60 TROUBLESHOOTING ..............61 Before Calling for Assistance ............62 When Calling for Assistance ............. 64 Return Material Authorization (RMA) Procedure ......65 www GarrettCom com...
  • Page 8 Shipping and Packaging Information ..........67 APPENDIX A: WARRANTY INFORMATION ......... 69 Revisions Rev A 05/08: Initial release of this user manual for CSG14 Converter Switches GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or model offerings without notice. www GarrettCom com...
  • Page 9: Specifications

    Filter and Forward Rate from 1000Mbps ports: 1,488,000 pps max. Filter and Forward Rate from 100Mbps ports: 148,800 pps max. Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max. Processing type: Store and Forward, non-blocking Auto-learning: 1K-address table Address buffer age-out time: 300 sec. www GarrettCom com...
  • Page 10 40 km (131,240 ft) 1000BASE-T (CAT5E OR HIGHER recommended) 100 m (328 ft) 1000BASE-SX, full duplex, multi-mode (62.5um) 220 m (722 ft) 1000BASE-SX, full duplex, multi-mode (50um) 550 m (1804 ft) 1000BASE-LX, full duplex, single-mode (9um) 5 km (16404 ft) www GarrettCom com...
  • Page 11 -40ºF to 212ºF (-40ºC to 100ºC) Cold Start: CSG14H to -20ºC CSG14P to -40ºC Ambient Relative Humidity: 5% to 95% (non-condensing) Altitude (All models): -200 to 50000ft. (-60 – 15,000 m) Conformal Coating (optional) for humidity protection www GarrettCom com...
  • Page 12 Convection on the CSG14 Series models. The hardened (H) factory floor and premium (P) temperature un-controlled location models have closed cases to withstand dirt and use special thermal techniques to transfer heat to the outside of the case for cooling. www GarrettCom com...
  • Page 13 Converter Switch ratings. Factory Floor (H) Ratings (-25 to 60°C) North America (-Hd) models. Hardened, factory floor temperature rated. Input: 6ft AC power cord to IEC 320 connector on the 100-240vac 47-63Hz external power adapter. Output: 12vdc, 1.25Amps www GarrettCom com...
  • Page 14 Input: IEC 320 connector on the 100-240vac 47-63Hz external power adapter. Requires a user supplied power cord. Output: 12vdc, 2Amps. Direct DC POWER SUPPLY: built-in terminal block for +, -, ground along with 12VDC jack 12V DC internal (range of 8.0 to 15V DC). www GarrettCom com...
  • Page 15 Note 1: the 8-15V DC jack can be used for dual source DC input using an AC adapter and the DC terminal block. Power supply protection is provided by internal diodes. Note 2: The Direct DC power floats. The user may ground either “+” or “-” if desired. www GarrettCom com...
  • Page 16 (UTP) Cat 3, 4, 5 cables. One Fiber optic port: The CSG14 series is 1000Base-SX / -LX / -ZX with a “fiber flavor” choice of multimode SC or SLC connectors Switches Fiber port default is FDX (Full-Duplex) RJ45’s are triple-speed auto-negotiating www GarrettCom com...
  • Page 17 Fiber port: LK/ACT: Steady ON for Link with no traffic, BLINKING for Activity Mounting options Metal mounting clips for panel mounting: included DIN-Rail mounting option: Model # DIN-RAIL MC2 (see Section 3.4) Rack-mount option: MC14-TRAY, see http://www.garrettcom.com/mc_tray.htm Mean Time Between Failure (MTBF ) – over15 years, Telcordia (Bellcore) Method www GarrettCom com...
  • Page 18 P model: IEEE P1613 Env. Std for Electric Power Substations P model: NEMA TS-2 and TEES for traffic control equipment P model: designed for UL 2043 above-the-ceiling installation IEC61850 EMC and Operating Conditions Class C Power Substations Warranty: Three years, return to factory Made in USA www GarrettCom com...
  • Page 19: Summary Of Models And Descriptions

    AC hardened power supply is not included CSG14H-ff-24VDC = Same as CSG14H-12VDC model, except 24VDC power input replaces 12VDC. CSG14HR-ff-24VDC = Same as CSG14H-24VDC model, but includes DIN-RAIL-MC2 mounting option. CSG14H-ff-48VDC = Same as CSG14H-24VDC model, except -48VDC power input replaces 24VDC www GarrettCom com...
  • Page 20 “SX” = 1000Base-SX-SC: 850nm multi-mode fiber optic with SC type connector, 550 m. “ESX”= 1000Base-SX Extended: 1310nm multi-mode fiber optic with SC type connector, 2 km “LX10”= 1000Base-LX-SLC: 1310nm multi-mode fiber optic with LC type connector, 10 km www GarrettCom com...
  • Page 21 Other Tray configurations with power supplies and power cabling included - See Section 3.3 DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one CSG14 Series Switch, See Section 3.4 Conformal Coating (for high humidity and “tropical” applications) - request quote. www GarrettCom com...
  • Page 22: Introduction

    Inspect the contents of this package for any signs of damage and ensure that the items listed below are included. This package should contain: Magnum CSG14 Series Converter Switch unit, External Power Supply, (for -Hd, -Hi, -Pd and -Pi models only) www GarrettCom com...
  • Page 23: Product Description

    Metal panel mounting clips and screws (2 each) User Guide (this manual) Remove the Magnum CSG14 Series Converter Switch from the shipping container. Be sure to keep the shipping container should you need to ship the unit at a later date.
  • Page 24 AC or DC input power selection and multiple application environments, and you have the Magnum CSG14 Converter Switch family. The Magnum CSG14 family of Converter Switches with a 1000Mb, 100Mb or 10Mb Fiber port built in covers the full range of application environments, with Hardened (factory floor), and Premium-rated (outdoor) versions.
  • Page 25 Mounting options include stand-alone panel mounting, DIN-Rail, or rack-mount tray. The Magnum CSG14P Premium-rated units are for temperature un-controlled applications (-40 to 75C), typically located outdoors. The CSG14P models are built with premium-grade extended temperature components, and use similar thermal techniques as www GarrettCom com...
  • Page 26 Converter Switch as a flexible option, which provides multiple solutions using very small space. Providing the combination of Media Converter with Switch, the CSG14 Series is an ideal choice for edge-of–the-network applications. www GarrettCom com...
  • Page 27 Choices of models for external AC or internal DC power are available. Ambient operating temperature is –25°C to + 60°C depending on the power source used. Storage temperature rating is –40°C to + 100°C www GarrettCom com...
  • Page 28 DIN-rail, or rack-mount tray. Choices of models for external AC or internal DC power are available. Ambient operating temperature is between –40°C to +75°C depending on the power source used. Storage temperature rating is between –40°C to +100°C. www GarrettCom com...
  • Page 29 The LK/ACT LED’s are repeated on the front as LA1 (port 1), LA2 (port 2), and LA3 (port 3). There is a power (PWR) indicator on the front of the unit to validate that the unit is turned ON. www GarrettCom com...
  • Page 30: Frame Buffering And Latency

    2.3 Frame Buffering and Latency The Magnum CSG14 Series Converter Switches are store-and-forward switches. Each frame (or packet) is loaded into the Switch’s memory and inspected before forwarding can occur. This technique ensures that all forwarded frames are of a valid length and have the correct CRC, i.e.
  • Page 31 To minimize the possibility of dropping frames on congested ports, each Magnum CSG14 Series Converter Switch dynamically allocates buffer space from 64Kb memory pool, ensuring that heavily used ports receive very large buffer space for packet storage.
  • Page 32 This dynamic buffer allocation provides the capability for the maximum resources of the Magnum CSG14 Series unit to be applied to all traffic loads, even when the traffic activity is unbalanced across the ports. Since the...
  • Page 33 Installation and User Guide (05/08) a second and is transparent to an observer. See Section 4.6 for additional details. Another feature implemented in Magnum CSG14 Series Converter Switches is a collision-based flow-control mechanism (when operating at half-duplex only). When the...
  • Page 34: Features And Benefits

    1000Mb, 100Mb or 10 Mb of bandwidth. Reduces Network Costs and provide economical solution Magnum CSG14 Series Switches offer the ideal solution to efficiently and inexpensively connect a Twisted Pair and fiber network with 10Mb, 100Mb or 1000Mb and help to expand the Ethernet network in a very convenient and economical way.
  • Page 35 Installation is “Plug and Play”, operation is transparent to software The Magnum CSG14 Series Switches operate as hardware switches, only forwarding those packets from each domain that are needed on the other domains. Internal address tables are self-learning, enabling users to change port connections or 10/100/1000 domains without affecting operations.
  • Page 36 Featuring a compact steel case with an external AC and internal DC power supply, Magnum CSG14 Series of Converter Switches can be installed in small spaces in cabinets, on table tops, in racks, wall or DIN rail mounted and in trays such as the Magnum MC14-TRAY.
  • Page 37: Applications For Csg14 Series Converter Switches

    Magnum Converter Switches are focused on providing easier, more economical and ultra-reliable industrial application products. The compactly designed Magnum CSG14 Series act as very useful tools in the modern life of fast expanding network requirements. The Triple-Speed and Dual-media functions support a mixed environment of 10 Mbps, 100Mbps and 1000Mbps users with copper and fiber media.
  • Page 38 The ruggedness of the CSG14P’s steel case and the high reliability of the design compliment the temperature-controlled packaging to provide an exceptional Ethernet product. www GarrettCom com...
  • Page 39 IBM Compatible Server Test computer 100Mb Servers 100Mb Servers and Workstations and Workstations 10Mb Servers 10Mb Servers Data and Workstations and Workstations Data Test computer CS14P Convenient Switches provided a secure dependable, reliable solution for un-controlled temp. environment www GarrettCom com...
  • Page 40 This need can be easily met using the economical Magnum CSG14 Converter Switch. Additional functionality includes the ability to transfer data across large distances with multi- or single–mode fiber while securing the LAN from EMI and wire-tapping. www GarrettCom com...
  • Page 41 Link/Act Error Error Speed Speed GARRETT GARRETT PORTS PORTS UPLINK UPLINK 100Mb Servers 100Mb Servers UPLINK UPLINK and Workstations Test Station Test Station Test Station CS14H Converter Switches provided a secure economical solution for expanding Industrial network www GarrettCom com...
  • Page 42 Built with high-grade components, efficient cooling techniques and having no openings for dirt to enter, the CSG14 Series Converter Switches provide the very effective solution for this need. www GarrettCom com...
  • Page 43 100Mb Servers 100Mb Servers 100Mb Servers 100Mb Servers 100Mb Servers and Workstations and Workstations and Workstations and Workstations and Workstations and Workstations Test Station CCTV Camera Test Station Test Station Test Station CCTV Camera CCTV Camera CCTV Camera www GarrettCom com...
  • Page 44 AC and DC power options. The second copper port at the remote location provides access for other Ethernet equipment such as motion detectors or will act as a test port for maintenance personnel with up-link for access to a central LAN and central file servers. www GarrettCom com...
  • Page 45: Installation

    CSG14 Series Gigabit Converter Switch Installation and User Guide (05/08) INSTALLATION This section describes the installation of the Magnum CSG14 Series Converter Switches, including location; mountings and power supply options and media connection. 3.1 Locating the Converter Switch Unit All the CSG14 Series Switches operate in transparent half-and full-duplex mode.
  • Page 46 CSG14 Series Gigabit Converter Switch Installation and User Guide (05/08) The compact and lightweight design of the Magnum CSG14 Series allows it to be easily installed in almost any location. A Velcro strip may be used for mounting the unit on a vertical surface such as a wall or cabinet, or for securing the unit on a table-top or shelf.
  • Page 47: Mc14-Tray For Rack Mounting Of Csg14 Series Switches

    CSG14 Series Gigabit Converter Switch Installation and User Guide (05/08) 3.2 MC14-TRAY for Rack Mounting of CSG14 Series Switches For 19” rack-mounting of Magnum CSG14 Series Converter Switches, a rack- mount tray is available, the MC14-TRAY. The Converter Switches are mounted with the...
  • Page 48: Mc14-Tr+Ps9 And X2 For Rack Mounting Media Converters

    19” rack-mount tray. These models come with built-in common universal AC power supply rated at 55 watts at 50°C ambient, 9 VDC regulated output, and supporting up to 10 Switches for MC14-TR+PS9 and 16 units CSG14 Series for MC14-TR+PS9X2. www GarrettCom com...
  • Page 49 CSG14, FT14 and 14E Media Converters, each with their power input plugged into the built-in common AC power supply in the rear area of the tray. (PS units that come with the MC’s are not used). www GarrettCom com...
  • Page 50: Din-Rail Mounting Option

    The metal DIN-Rail mounting hardware is optional and needs to be ordered as a separate item, e.g. Model #DIN-RAIL-MC2. It comes with four screws to attach the bracket to the MC unit. The rail clip is spring-loaded with a pull-up latch at the top for easy “snap-on” attachment and removal. www GarrettCom com...
  • Page 51: Power Requirements, Csg14 Series Switches

    CSG14 Series Gigabit Converter Switch Installation and User Guide (05/08) The Magnum CSG14 models with “HR” have 24VDC power, and have the DIN- Rail-MC2 bracket included and assembled with the MC unit at the factory. 3.5 Power Requirements, Power Supply Types for CSG14 Series Switches Magnum CSG14 Series Switches are power-efficient and can work with an external AC power supply.
  • Page 52 Note: When connected to a -48 V centralized dc source these products are to be installed only in Restricted Access Areas (dedicated equipment rooms, electrical closets or the like). www GarrettCom com...
  • Page 53: Powering The Csg14H And Csg14P (Dc Internal)

    12VDC, 24VDC or -48VDC power. DC power input may be chosen for high-availability. The extended temperature capability of the DC-powered CSG14P’s can go temperature uncontrolled environments, rated at –40`C to +75`C. If indoors, the DC jack is www GarrettCom com...
  • Page 54 8 - 15V DC (12V DC) 18 – 36V DC (24V DC) 36 – 60V DC (-48V DC) Input current: 0.8 amp.(12V DC) 0.4 amp max.(24V DC) 0.2 amp max.(-48V DC) Power Consumption: 4 watts typical, 5 watts max. www GarrettCom com...
  • Page 55: Csg14H And P Series , Dc-Powered, Installation

    The power terminals are identified as positive (+) and negative (-), and they are floating inside the unit so that the user if desired may ground either of the terminals. The chassis is “earth” or ground (GND). www GarrettCom com...
  • Page 56: Connecting Ethernet Media

    When power is applied, the green PWR LED will illuminate. 3.8 Connecting Ethernet Media The Magnum CSG14 Series Converter Switch can be connected to two media types i.e. fiber and copper (RJ-45) types, run at 1000BASE-T, 100BASE-TX, 10BASE-T and 1000BASE-SX/LX/ZX, 100BASE-FX, or 10BASE-FL. CAT 5E cables should be...
  • Page 57 Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45 Twisted Pair (CAT 5) 100BASE-TX RJ-45 Twisted pair (CAT5E or Higher) 1000BASE-T RJ-45 Fiber (Multi-mode) 10BASE-FL Fiber (Multi-mode) 100BASE-FX Fiber (Single-mode) 100BASE-FX SC, LC Fiber (Multi-mode, Single-mode) 1000BASE-SX SC, LC Fiber (Single-mode) 1000BASE-LX/ZX www GarrettCom com...
  • Page 58: Connecting Twisted Pair

    RJ-45 connector of the port. Note that, even though the connector is shielded, either unshielded or shielded cables and wiring may be used. Connect the other end of the cable to the corresponding device. Use the LINK LED to ensure proper connectivity by noting that the LED will be www GarrettCom com...
  • Page 59: Connecting Fiber Optic Lc-Type, "Small Form Factor (Sff)

    The following procedure applies to installations using SC-type fiber connectors, i.e., using multi-mode SC. While connecting fiber media to SC connectors, simply snap on the two square male connectors into the SC female jacks of the Fiber connector until it clicks and secures. www GarrettCom com...
  • Page 60: Connecting Single-Mode Fiber Optic

    To calculate the power budget of different fiber media installations using Magnum products, the following equations should be used: OPB (Optical Power Budget) = P (min) - P (min) where P = Transmitter Output Power, and P = Receiver Sensitivity www GarrettCom com...
  • Page 61 “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km The following data has been collected from component manufacturer’s (HP’s, and Siemens’) web sites and catalogs to provide guidance to network designers and installers www GarrettCom com...
  • Page 62 Single 1000Mb CSG14- -mode 1310 9/125 -9.5 10.5 LX10 1000Mb Single CSG14- 9/125 -4.0 37.5 17.5 1310 -mode LX25 Single 1000Mb CSG14- -mode 9/125 -4.0 17.5 1550 ZX40 Single 1000Mb CSG14- -mode 9/125 -3.0 20.5 1550 ZX70 www GarrettCom com...
  • Page 63: Connections To Nics Which Support Auto-Neg Rj-45 Ports

    3.8.6 Connections to NICs which support Auto-Negotiation, RJ-45 ports The copper ports of Magnum CSG14 Series Converter Switches will function properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the Fast Link Pulse (FLP) coding for the 1000BASE-T signaling system. When connecting a...
  • Page 64: Operation

    “communicate” with 100Mbps users as well as other 10 Mbps users through the switch. Similarly, the 100Mbps traffic obeys the rules of 100Mbps Ethernet, and can communicate with 10 Mb and 100Mb users. Magnum CSG14 Series units are plug-and-play devices. There is no software www GarrettCom com...
  • Page 65 Packets needed for maintaining the operation of the network (such as occasional multi-cast packets) are forwarded to all ports. The Magnum CSG14 Series Converter Switches operate in the store-and-forward switching mode, which...
  • Page 66: Auto-Cross (Mdix), Auto-Negotiation And Speed-Sensing

    Switching, Address Learning The Magnum CSG14 Series units have address table capacity of 1K node addresses, and are suitable for use in large networks. They are self-learning, so that as nodes are added or removed or moved from one segment to another, the CSG14 Series switch automatically keeps up with node locations.
  • Page 67 10, 100 or 1000Mbps speed and F/H duplex mode, and the device at the other end of the cable should similarly advertise / respond. Both sides will agree to the speed and mode to be used per the IEEE 802.3z standard. Depending upon www GarrettCom com...
  • Page 68: Dual Leds, Front-Panel And Side-Panel

    The Link ports are also represented by LA1, LA2, and LA3. (Steady On or steady Off indicates no Receive Activity). Steady ON for 1000Mb speed, OFF for 100Mb or 10Mb speed per port www GarrettCom com...
  • Page 69: Troubleshooting

    However, if you are unsure of the procedures described in this section or if the Magnum CSG14 Series 10/100/1000 Mb/s Switch is not performing as expected, do not attempt to repair the unit; instead contact your...
  • Page 70: Before Calling For Assistance

    CSG14 Series Gigabit Converter Switch Installation and User Guide (05/08) supplier for assistance or contact GarrettCom Customer Support. 5.1 Before Calling for Assistance If difficulty is encountered when installing or operating the unit, refer back to the Installation Section of the applicable chapter of this manual. Also check to make sure that the various components of the network are interoperable.
  • Page 71 Magnum CSG14 Series Switch and its associated cables are functioning properly. If the problem continues after completing Step 4 above, contact your supplier of the Magnum CSG14 Series 10/100/1000 Mb/s Switch unit or if unknown, contact GarrettCom, Inc by fax, phone or email (support@garrettcom.com) for assistance.
  • Page 72: When Calling For Assistance

    The components involved in the problem; d. Any particular application that, when used, appears to create the problem; An accurate list of GarrettCom product model(s)involved, with serial number(s). Include the date(s) that you purchased the products from your supplier.
  • Page 73: Return Material Authorization (Rma) Procedure

    Please have the following information readily available: Name and phone number of your contact person. Name of your company / institution Your shipping address Product name Serial Number (or Invoice Number) www GarrettCom com...
  • Page 74 Date of installation Failure symptoms, including a full description of the problem. GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty- repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete details).
  • Page 75 (user) charge. 5.4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions: 1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for shipping protection.
  • Page 76 This material may cause electro-static shock damage to the unit. 2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container. 3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to: GarrettCom, Inc.
  • Page 77 GarrettCom, Inc. warrants its products to be free from defects in materials and workmanship for a period of three (3) years from the date of shipment by GarrettCom. During this warranty period, GarrettCom will repair or, at its option, replace components in the products that prove to be defective at no charge other than shipping and handling, provided that the product is returned pre-paid to GarrettCom.

Table of Contents