  • Page 1 Magnum CS14 and CSN14 Converter Switches 100Mb Fiber 10 Mb Fiber Installation and User Guide www GarrettCom com...
  • Page 2 Magnum CS14 or CSN14 10/100 Mb/s Converter Switch products, consult Section 5, Troubleshooting, of this User Guide. Copyright © 2006 GarrettCom, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from GarrettCom, Inc.
  • Page 3 Operation of this equipment in a residential area is likely to cause interference, in which case the user, at his own expense, will be required to take whatever measures may be required to correct the interference. www GarrettCom com...
  • Page 4 CS14, CSN14 Series Converter Switch Installation and User Guide (02/06) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Drive Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com...
  • Page 5: Table Of Contents

    MC14-TRAY for Rack Mounting of CS14 Series Switches .... 40 3.3 MC14-TR+PS9 and X2 for Rack Mounting Media Converters ... 41 DIN-Rail mounting option..............43 Power Requirements, CS14 and CSN14 Series Switches....44 3.6 Powering the CS14H, CSN14H and CS14P, CSN14P (DC internal)..46 www GarrettCom com...
  • Page 6 Dual-Speed Functionality, and Switching ......... 57 Auto-cross (MDIX), Auto-negotiation and Speed-sensing....59 4.3 (F- H) Switch, Full-Duplex or Half-Duplex options for Fiber port# 1. 60 Dual LEDs, Front-panel and side-panel (Magnum CS14 and CSN14)61 TROUBLESHOOTING ..............62 Before Calling for Assistance ............63 When Calling for Assistance .............
  • Page 7 Rev A 07/04: Minor updates on Agency approvals and power supplies Rev A 05/04: Initial release of this user manual for CS14 Converter Switches GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or model offerings without notice. www GarrettCom com...
  • Page 8: Specifications

    Auto-sensing for speed: IEEE 802.3u Packet-Processing Between Domains Filter and Forward Rate from 100Mbps ports: 148,800 pps max Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max. Processing type: Store and Forward, non-blocking Auto-learning: 2K address table www GarrettCom com...
  • Page 9 - 412 m (1350 ft) 100BASE-FX, full-duplex: (single-mode) - 20 km (65,620 ft) 100BASE-FX, full-duplex: (single-mode, long reach) - 40 km (131,240 ft) 10BASE-FL, Fiber optic - 2 km (6,562 ft) 10BASE-FL, Single-mode Fiber optic - 10 km (32,810ft) www GarrettCom com...
  • Page 10 Ambient Relative Humidity: 5% to 95% (non-condensing) Altitude (All models): -200 to 5000ft. (-60 – 15,000 m) Conformal Coating (optional) for humidity protection Note: H and P models are designed for NEBS compliance, including, vibration, shock and altitude. www GarrettCom com...
  • Page 11 Convection on the regular model. The hardened (H) factory floor and premium (P) temperature un-controlled location models have closed cases to withstand dirt and use special thermal techniques to transfer heat to the outside of the case for cooling. www GarrettCom com...
  • Page 12 All models have an (8-15)VDC output with 6ft long cord and a 2.5mm center +ve jack. The power supplies are temperature rated to match the Converter Switch ratings. Office Ratings (0 to 40°C) North America (-d) models. Input: direct plug-in 95-125vac at 60 Hz. Output:12vdc, 1Amps www GarrettCom com...
  • Page 13 North America (-Pd) models. Outdoor temperature rated. Input: 6ft AC power cord to IEC 320 connector on the100-240vac 47-63Hz external power adapter. Output:12vdc, 2Amps. International (-Pi) models. Outdoor temperature rated. Input: IEC 320 connector on the 100-240vac 47-63Hz external power adapter. Requires a user supplied power cord. Output:12vdc, 2Amps. www GarrettCom com...
  • Page 14 Note 1: the 8-15V DC jack can be used for dual source DC input using an AC adapter and the DC terminal block. Power supply protection is provided by internal diodes. Note 2: The Direct DC power floats. The user may ground either “+” or “-” if desired. www GarrettCom com...
  • Page 15 Fiber Port # 1 is controlled by an “F – H” switch, provided underneath it. “F” enables full-duplex mode and “H” enables half-duplex mode. The default setting is “F” for 100Mb fiber models, “H” for 10Mb fiber models. www GarrettCom com...
  • Page 16 Steady ON for full-duplex, OFF for half-duplex Mounting options Metal mounting clips for panel mounting: included DIN-Rail mounting option: Model # DIN-RAIL MC2 (see Section 3.4) Rack-mount option: MC14-TRAY, see http://www.garrettcom.com/mc_tray.htm Mean Time Between Failure (MTBF ) – over15 years, Telcordia (Bellcore) Method www GarrettCom com...
  • Page 17 H and P models: IEEE P1613 Env. Std for Electric Power Substations P models: NEMA TS-2 and TEES for traffic control equipment P models: designed for UL 2043 above-the-ceiling installation IEC61850 EMC and Operating Conditions Class C Power Substations Warranty: Three years, return to factory Made in USA www GarrettCom com...
  • Page 18: Summary Of Models And Descriptions

    CSN14P-12VDC = Same as CS14P-Pd, Pi, except AC Premium Power Supply is not included. CSN14P-24VDC = Same as CS14P-12VDC model, except 24VDC power input replace 12VDC. CSN14PR-24VDC = Same as CS14P-24VDC model, but includes DIN-RAIL-MC2 mounting option. CSN14P-48VDC = Same as CS14P-24VDC model, except -48VDC input replaces 24VDC. www GarrettCom com...
  • Page 19 CS14P-ff-24VDC = Same as CS14P-12VDC model, except 24VDC power input replace 12VDC. CS14PR-ff-24VDC = Same as CS14P-24VDC model, but includes DIN-RAIL-MC2 mounting option. CS14P-ff-48VDC = Same as CS14P-24VDC model, except -48VDC input replaces 24VDC. The “ff” field is for selection of the desired “fiber flavor” as listed below. www GarrettCom com...
  • Page 20 Other Tray configurations with power supplies and power cabling included - See Section 3.3 DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one CS14 and CSN14 Series Switch, See Section 3.4 Conformal Coating (for high humidity and “tropical” applications) - request quote. www GarrettCom com...
  • Page 21: Introduction

    Inspect the contents of this package for any signs of damage and ensure that the items listed below are included. This package should contain: Magnum CS14- or CSN14-Series Converter Switch unit, External Power Supply, (for -d, -i, -Hd, -Hi, -Pd and -Pi models only) 1 set...
  • Page 22: Product Description

    AC or DC input power selection and multiple application environments, and you have the Magnum CS14 and CSN14 Converter Switch family. The Magnum CS14 and CSN14 family of Converter Switches with a 100 Mb or 10Mb Fiber port built in covers the full range of application environments, with regular (office), Hardened (factory floor), and Premium-rated (outdoor) versions.
  • Page 23 The Magnum CS14 and CSN14 regular-package units are for office and indoor wiring closet environments. These are the economical base units in the CS14 and CSN14 Switch family.
  • Page 24 The Magnum CS14P and CSN14P Premium-rated units are for temperature un- controlled applications (-40 to 75C), typically located outdoors. The CS14P and CSN14P models are built with premium-grade extended temperature components, and use similar thermal techniques as the CS14H Hardened units. In addition to a Premium-rated AC www GarrettCom com...
  • Page 25 Converter Switch as a flexible option, which provides multiple solutions using very small space. Providing the combination of Media Converter with Switch, the CS14 and CSN14 Series is an ideal choice for edge-of–the-network applications. www GarrettCom com...
  • Page 26 Installation and User Guide (02/06) YELLOW labeled Magnum CS14 and CSN14 models (as shown in Fig 2.2.a) units are for office and wiring closet environments and use an external AC power supply. A ventilated metal case for convection cooling is featured. Ambient operating temperature is 0°...
  • Page 27 Choices of models for external AC or internal DC power are available. Ambient operating temperature is –25°C to + 60°C depending on the power source used. Storage temperature rating is –25°C to + 85°C Fig 2.2.b CS14H with 100Mb SC connector www GarrettCom com...
  • Page 28 DIN-rail, or rack-mount tray. Choices of models for external AC or internal DC power are available. Ambient operating temperature is between –40°C to +75°C depending on the power source used. Storage temperature rating is between –40°C to +85°C. Fig 2.2c CS14P with 100Mb SC Connector www GarrettCom com...
  • Page 29 (PWR) indicator on the front of the unit to validate that the unit is turned ON. The single fiber port on the CSN14’s is multi-mode with an ST connector and , on the CS14’s, it is an SC, ST or small form-factor connector (MTRJ multi mode or LC www GarrettCom com...
  • Page 30: Frame Buffering And Latency

    2.3 Frame Buffering and Latency The Magnum CS14 and CSN14 Series Converter Switches are store-and-forward switches. Each frame (or packet) is loaded into the Switch’s memory and inspected before forwarding can occur. This technique ensures that all forwarded frames are of a valid length and have the correct CRC, i.e.
  • Page 31 To minimize the possibility of dropping frames on congested ports, each Magnum CS14 and CSN14 Series Converter Switch dynamically allocates buffer space from 128Kb memory pool, ensuring that heavily used ports receive very large buffer space for packet storage.
  • Page 32 When the port buffer fills up, dropped packets result.) This dynamic buffer allocation provides the capability for the maximum resources of the Magnum CS14 and CSN14 Series unit to be applied to all traffic loads, even when the traffic activity is unbalanced across the ports.
  • Page 33 CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) Another feature implemented in Magnum CS14 and CSN14 Series Converter Switches is a collision-based flow-control mechanism (when operating at half-duplex only). When the Switch detects that its free buffer queue space is low, the Switch prevents more frames from entering by forcing a collision signal on all receiving half-duplex ports in order to stop incoming traffic.
  • Page 34: Features And Benefits

    100Mb (or 10 Mb) of bandwidth. Reduces Network Costs and provide economical solution Magnum CS14 and CSN14 Series Switches offer the ideal solution to efficiently and inexpensively connect a Twisted Pair and fiber network with 10Mb or 100Mb and help to expand the Ethernet network in a very convenient and economical way.
  • Page 35 Installation and User Guide (02/06) Installation is “Plug and Play”, operation is transparent to software The Magnum CS14 and CSN14 Series Switches operate as hardware switches, only forwarding those packets from each domain that are needed on the other domains. Internal address tables are self-learning, enabling users to change port connections or 10/100 domains without affecting operations.
  • Page 36 Featuring a compact steel case with an external AC and internal DC power supply, Magnum CS14 and CSN14 Series of Converter Switches can be installed in small spaces in cabinets, on table tops, in racks, wall or DIN rail mounted and in trays such as the Magnum MC14-TRAY.
  • Page 37: Applications For Cs14 And Csn14 Series Converter Switches

    The edge-of-the-network connectivity solutions offered by Magnum Converter Switches are focused on providing easier, more economical and ultra-reliable industrial application products. The compactly designed Magnum CS14 and CSN14 Series act as very useful tools in the modern life of fast expanding network requirements. The Dual-Speed and Dual- media functions support a mixed environment of 10 Mbps and 100Mbps users with copper and fiber media.
  • Page 38 The ruggedness of the CS14P’s steel case and the high reliability of the design compliments the temperature controlled packaging to provide an exceptional Ethernet product. www GarrettCom com...
  • Page 39 IBM Compatible Server Test computer 100Mb Servers 100Mb Servers and Workstations and Workstations 10Mb Servers 10Mb Servers Data and Workstations and Workstations Data Test computer CS14P Convenient Switches provided a secure dependable, reliable solution for un-controlled temp. environment www GarrettCom com...
  • Page 40 This need can be easily met using the economical Magnum CS14 or CSN14 Converter Switch. Additional functionality includes the ability to transfer data across large distances with multi- or single–mode fiber while securing the LAN from EMI and wire tapping. www GarrettCom com...
  • Page 41 Error GARRETT GARRETT POR TS POR TS U PLINK U PLINK 100Mb Servers 100Mb Servers UPLINK UPLINK and Workstations Test Station Test Station Test Station CS14H Converter Switches provided a secure economical solution for expanding Industrial network www GarrettCom com...
  • Page 42 Built with high-grade components, efficient cooling techniques and having no openings for dirt to enter, the CS14 and CSN14 Series Converter Switches provide the very effective solution for this need. www GarrettCom com...
  • Page 43 100Mb Servers 100Mb Servers 100Mb Servers 100Mb Servers 100Mb Servers and Workstations and Workstations and Workstations and Workstations and Workstations and Workstations Test Station CCTV Camera Test Station Test Station Test Station CCTV Camera CCTV Camera CCTV Camera www GarrettCom com...
  • Page 44 Ethernet equipment such as motion detectors or will act as a test port for maintenance personnel with up-link for access to a central LAN and central file servers. www GarrettCom com...
  • Page 45: Installation

    CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) INSTALLATION This section describes the installation of the Magnum CS14 and CSN14 Series Converter Switches, including location, mountings, power supply options and media connection. 3.1 Locating the Converter Switch Unit...
  • Page 46 Alternatively, metal mounting clips and screws are included for a rugged and secure mounting in any orientation. Installation of the Magnum CS14 and CSN14 Series Converter Switches is a simple procedure. The installation location is dependent upon the physical layout of the Ethernet network and associated cabling.
  • Page 47: Mc14-Tray For Rack Mounting Of Cs14 Series Switches

    CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) 3.2 MC14-TRAY for Rack Mounting of CS14 and CSN14 Series Switches For 19” rack- mounting of Magnum CS14 and CSN14 series Converter Switches, a rack-mount tray is available, the MC14-TRAY.
  • Page 48: Mc14-Tr+Ps9 And X2 For Rack Mounting Media Converters

    19” rack-mount tray. These models come with built-in common universal AC power supply rated at 55 watts at 50°C ambient, 12VDC output, and supporting up to 10 Switches for MC14-TR+PS9 and 16 units CS14 and CSN14 Series for MC14-TR+PS9X2. The MC14- www GarrettCom com...
  • Page 49 CS14 and CSN14, FT14 and 14E Media Converters, each with their power input plugged into the built-in common AC power supply in the rear area of the tray. (PS units that come with the MC’s are not used). www GarrettCom com...
  • Page 50: Din-Rail Mounting Option

    The metal DIN-Rail mounting hardware is optional and needs to be ordered as a separate item, e.g. Model #DIN-RAIL-MC2. It comes with four screws to attach the bracket to the MC unit. The rail clip is spring-loaded with a pull-up latch at the top for easy “snap-on” attachment and removal. www GarrettCom com...
  • Page 51: Power Requirements, Cs14 And Csn14 Series Switches

    CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) The Magnum CS14 and CSN14 models with “HR” have 24VDC power, and have the DIN-Rail-MC2 bracket included and assembled with the MC unit at the factory. 3.5 Power Requirements, Power Supply Types for CS14 and CSN14 Series Switches Magnum CS14 and CSN14 Series Switches are power-efficient and can work with an external AC power supply.
  • Page 52 Note: When connected to a -48 V centralized dc source these products are to be installed only in Restricted Access Areas (dedicated equipment rooms, electrical closets or the like). www GarrettCom com...
  • Page 53: Powering The Cs14H, Csn14H And Cs14P, Csn14P (Dc Internal)

    The extended temperature capability of the DC-powered CS14P’s can go temperature uncontrolled environments, rated at –40`C to +75`C. If indoors, the DC jack is also present and optionally can be used with an external AC power supply. www GarrettCom com...
  • Page 54 8 - 15V DC (12V DC) 18 – 36V DC (24V DC) 36 – 60V DC (-48V DC) Input current: 0.8 amp.(12V DC) 0.4 amp max.(24V DC) 0.2 amp max.(-48V DC) Power Consumption: 4.8 watts typical, 6 watts maxm. www GarrettCom com...
  • Page 55: Cs14, Csn14 Series Converter Switch Installation And User Guide

    The chassis is “earth” or ground (GND). The connection procedure is straightforward. Simply insert the DC leads to the CS14H’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) www GarrettCom com...
  • Page 56: Connecting Ethernet Media

    When power is applied, the green PWR LED will illuminate. 3.8 Connecting Ethernet Media The Magnum CS14 and CSN14 Series Converter Switch can be connected to two media types i.e. fiber and copper (RJ-45) types, runt at 100BASE-TX, 10BASE-T and 100BASE-FX, or 10BASE-FL.
  • Page 57 100Mbps) be used whenever possible in order to provide flexibility in a mixed-speed network, since P80-series switch ports are auto-sensing for either 10 and 100Mbps. Note that the auto-cross function does not operate, if the port is fixed or not supporting auto-negotiation. www GarrettCom com...
  • Page 58: Connecting Twisted Pair

    For Port # 1 or 1SW, if the LINK LED is not illuminated, move the switch which has a cross-over or up-link for linking to another hub or Switch. www GarrettCom com...
  • Page 59: Connecting Fiber Optic St-Type, "Twist-Lock

    Use the non-color coded fiber strand for this. The LINK LED on the front of the fiber connector will illuminate when a proper connection has been established at both ends (and when power is ON in the unit). If www GarrettCom com...
  • Page 60: Connecting Fiber Optic Sc-Type, "Snap-In

    Single-mode fiber allows full bandwidth at longer distances, about 20Km with the multi-mode SC. The same procedures as for multi-mode fiber apply to single-mode fiber connectors. Follow the steps listed in Section 3.8.2 above. www GarrettCom com...
  • Page 61: Power Budget Calculations For Cs14 Series, Fiber Media

    “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km The following data has been collected from component manufacturer’s (HP’s, and Siemens’) web sites and catalogs to provide guidance to network designers and installers www GarrettCom com...
  • Page 62 (0.4) 50/125 -23.5 12.2 MTRJ Single- 100Mb 9/125 32.5 Long Reach 1300 mode (0.4) 62.5/125 -15.0 CSN14- 10 Mb Multi- 100/140 -9.5 19.5 23.5 mode 50/125 -19.5 13.5 CSN14- Single- 10 Mb 1300 9/125 single-mode mode www GarrettCom com...
  • Page 63: Connections To Nics Which Support Auto-Neg Rj-45 Ports

    3.8.6 Connections to NICs which support Auto-Negotiation, RJ-45 ports The copper ports of Magnum CS14-Sereis Converter Switches will function properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the Fast Link Pulse (FLP) coding for the 100BASE-TX signaling system. When connecting a...
  • Page 64: Operation

    Similarly, the 100Mbps traffic obeys the rules of 100Mbps Ethernet, and can communicate with 10 Mb and 100Mb users. Magnum CS14 and CSN14 Series units are plug-and-play devices. There is no software configuring to be done at installation or for maintenance. The only hardware...
  • Page 65 Packets needed for maintaining the operation of the network (such as occasional multi-cast packets) are forwarded to all ports. The Magnum CS14 and CSN14 Series Converter Switches operate in the store-and-forward switching mode, which...
  • Page 66: Auto-Cross (Mdix), Auto-Negotiation And Speed-Sensing

    Switching, Address Learning The Magnum CS14 and CSN14 Series units have address table capacity of 2K node addresses, and are suitable for use in large networks. They are self-learning, so that as nodes are added or removed or moved from one segment to another, the CS14- and CSN14- Series switch automatically keeps up with node locations.
  • Page 67: F- H) Switch, Full-Duplex Or Half-Duplex Options For Fiber Port

    4.3 (F- H) Switch, Full-Duplex or Half-Duplex options for Fiber port# 1 The (F–H) manual switch has been provided for fiber port #1, for fixing that port at Full or Half Duplex as per the requirements. The (F-H) manual switch is being www GarrettCom com...
  • Page 68: Dual Leds, Front-Panel And Side-Panel (Magnum Cs14 And Csn14)61

    100Mb being set at Full-Duplex as default from the factory. The port can be set at the required mode, by sliding the manual switch position to “F” or “H”. 4.4 Dual LEDs, Front-panel and side-panel (Magnum CS14 and CSN14) Description Illuminates GREEN to indicate power applied.
  • Page 69: Troubleshooting

    However, if you are unsure of the procedures described in this section or if the Magnum CS14 and CSN14 Series 10/100 Mb/s Switch is not performing as expected, do not attempt to repair the unit; instead contact your supplier for assistance or contact GarrettCom Customer Support.
  • Page 70: Before Calling For Assistance

    Make sure that an AC power cord is properly attached to each Magnum CS14 and CSN14 Series unit. Be certain that the AC power cord is plugged into a functioning electrical outlet. Use the PWR LEDs to verify each unit www GarrettCom com...
  • Page 71 If the problem continues after completing Step 4 above, contact your supplier of the Magnum CS14 and CSN14 Series 10/100 Mb/s Switch unit or if unknown, contact GarrettCom, Inc by fax, phone or email (support@garrettcom.com) for assistance.
  • Page 72: When Calling For Assistance

    The components involved in the problem; d. Any particular application that, when used, appears to create the problem; An accurate list of GarrettCom product model(s)involved, with serial number(s). Include the date(s) that you purchased the products from your supplier.
  • Page 73: Return Material Authorization (Rma) Procedure

    Name and phone number of your contact person. Name of your company / institution Your shipping address Product name Serial Number (or Invoice Number) Packing List Number (or Sales Order Number) Date of installation Failure symptoms, including a full description of the problem. www GarrettCom com...
  • Page 74 CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete details).
  • Page 75 Installation and User Guide (02/06) 5.4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions: 1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for shipping protection.
  • Page 76 GarrettCom, Inc. warrants its products to be free from defects in materials and workmanship for a period of three (3) years from the date of shipment by GarrettCom. During this warranty period, GarrettCom will repair or, at its option, replace components in the products that prove to be defective at no charge other than shipping and handling, provided that the product is returned pre-paid to GarrettCom.