GarrettCom Magnum CSG14 Series Installation And User Manual

GarrettCom Magnum CSG14 Series Installation And User Manual

Gigabit converter switch
Hide thumbs Also See for Magnum CSG14 Series:

Advertisement

Magnum CSG14 Gigabit Converter Switches
CSG14U
CSG14
Installation and User Guide
www GarrettCom com
.
.

Advertisement

Table of Contents
loading

Summary of Contents for GarrettCom Magnum CSG14 Series

  • Page 1 Magnum CSG14 Gigabit Converter Switches CSG14U CSG14 Installation and User Guide www GarrettCom com...
  • Page 2 Installation and User Guide Part #: 84-00102Z Rev. F Trademarks GarrettCom is a registered trademark and Magnum, Dymec, DynaStar, Personal Switch, Link-Loss-Learn, S-Ring, Convenient Switch and Converter Switch are trademarks of GarrettCom, Inc. Ethernet is a trademark of Xerox Corporation...
  • Page 3 Magnum CSG14 10/100/1000 Mb/s Converter Switch products, consult Section 5, Troubleshooting, of this User Guide. Copyright © 2008 GarrettCom, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from GarrettCom, Inc.
  • Page 4 Operation of this equipment in a residential area is likely to cause interference, in which case the user, at his/her own expense, will be required to take whatever measures may be required to correct the interference. www GarrettCom com...
  • Page 5 Class 2, or listed ITE Power Supply, marked LPS, which has suitably rated output voltage (i.e. 24VDC or 48VDC) and suitable rated output current. Product does not contain user replaceable fuses. Any internal fuses can ONLY be replaced by GarrettCom personnel through the RMA process. www GarrettCom com...
  • Page 6 CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Drive Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com...
  • Page 7: Table Of Contents

    Features and Benefits ................. 32     Applications for CSG14 Series Converter Switches ......35     INSTALLATION ................. 44     Locating the Converter Switch Unit ..........44     MC14-TRAY for Rack Mounting of CSG14 Series Switches ..46 www GarrettCom com...
  • Page 8     3.8.6 Power Budget Calculations for CSG14 Series, Fiber Media ..59     3.8.7 Connections to NICs which support Auto-Negotiation ..... 61     OPERATION ..................62     Triple-Speed Functionality, and Switching ........62 www GarrettCom com...
  • Page 9 CSG14U model Rev C 11/08: removed PCSG14P model, added mounting hole location drawing (page 43) Rev B 08/08: added PCSG14P (PoE version) Rev A 05/08: Initial release of this user manual for CSG14 Converter Switches www GarrettCom com viii...
  • Page 10: Specifications

    Filter and Forward Rate from 1000Mbps ports: 1,488,000 pps max. Filter and Forward Rate from 100Mbps ports: 148,800 pps max. Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max. Processing type: Store and Forward, non-blocking Auto-learning: 1K-address table Address buffer age-out time: 300 sec. www GarrettCom com...
  • Page 11 40 km (131,240 ft) 1000BASE-T (CAT5E OR CAT6 recommended) 100 m (328 ft) 1000BASE-SX, full duplex, multi-mode (62.5um) 220 m (722 ft) 1000BASE-SX, full duplex, multi-mode (50um) 550 m (1804 ft) 1000BASE-LX, full duplex, single-mode (9um) 5 km (16404 ft) www GarrettCom com...
  • Page 12 -40ºF to 212ºF (-40ºC to 100ºC) Cold Start: CSG14H / CSG14UH to -20ºC CSG14P / CSG14UP to -40ºC Ambient Relative Humidity: 5% to 95% (non-condensing) Altitude (All models): -200 to 50,000ft. (-60 – 15,000 m) Conformal Coating (optional) for humidity protection www GarrettCom com...
  • Page 13 Convection on the CSG14 Series models. The hardened (H) factory floor and premium (P) temperature un-controlled location models have closed cases to withstand dirt and use special thermal techniques to transfer heat to the outside of the case for cooling. www GarrettCom com...
  • Page 14: Power Supply

    IEC 320 connector on the 100-240vac 47-63Hz external power adapter. Output: 12vdc, 1.25Amps International (-Hi) models. Factory floor temperature rated. Input: IEC 320 connector on the 100-240vac 47-63Hz external power adapter. Requires a user supplied power cord Output: 12vdc, 1.25Amps. www GarrettCom com...
  • Page 15 Direct DC POWER SUPPLY: built-in terminal block for +, -, ground along with 12VDC jack 12V DC internal (range of 8.0 to 15V DC) 24V DC internal (range of 18 to 36V DC). -48V DC internal (range of 36 to 60V DC), -, ground www GarrettCom com...
  • Page 16 It is shielded 8-pin female connector for shielded (STP) and unshielded (UTP) Cat 3, 4, 5 cables. Two Fiber optic ports: The CSG14U series is 100Base-FX or 1000Base-SX /-LX / -ZX with a “fiber flavor” choice of multimode or singlemode SFP connectors. www GarrettCom com...
  • Page 17 User may select 100Mb speed via DIP switch on the back of the unit Each SFP port is individually speed-selectable NOTE: After changing the speed switch setting, power cycle the unit for the speed setting to take effect. www GarrettCom com...
  • Page 18 POWER: Steady ON when power applied 10/100/Gb per RJ45 port: Steady ON for 100Mb, LK/ACT OFF for 10Mb, BLINKING for Gb LK/ACT Fiber port: LK/ACT: Steady ON for Link with no traffic, BLINKING for Activity PORT 3 www GarrettCom com...
  • Page 19 P model: IEEE P1613 Env. Std for Electric Power Substations P model: NEMA TS-2 and TEES for traffic control equipment P model: designed for UL 2043 above-the-ceiling installation IEC61850 EMC and Operating Conditions Class C Power Substations Warranty: Three years, return to factory Made in USA www GarrettCom com...
  • Page 20: Summary Of Models And Descriptions

    AC hardened power supply is not included CSG14H-ff-24VDC = Same as CSG14H-12VDC model, except 24VDC power input replaces 12VDC. CSG14HR-ff-24VDC = Same as CSG14H-24VDC model, but includes DIN-RAIL-MC2 mounting option. CSG14H-ff-48VDC = Same as CSG14H-24VDC model, except -48VDC power input replaces 24VDC www GarrettCom com...
  • Page 21 “SX” = 1000Base-SX-SC: 850nm multi-mode fiber optic with SC type connector, 550 m. “ESX”= 1000Base-SX Extended: 1310nm multi-mode fiber optic with SC type connector, 2 km “LX10”= 1000Base-LX-SLC: 1310nm single-mode fiber optic with LC type connector, 10 km www GarrettCom com...
  • Page 22 (-25 to 60C) using a direct DC ( 8-15VDC) and/or external AC hardened power supply (included). CSG14UH-ff-12VDC = Same as CSG14UH model, except AC hardened power supply is not included CSG14UH-ff-24VDC = Same as CSG14UH-12VDC model, www GarrettCom com...
  • Page 23 Same as CSG14UP-Pd, Pi, except AC Premium Power Supply is not included. CSG14UP-ff-24VDC = Same as CSG14UP-12VDC model, except 24VDC power input replaces 12VDC. CSG14UPR-ff-24VDC = Same as CSG14UP-24VDC model, but includes DIN-RAIL-MC2 mounting option. CSG14UP-ff-48VDC = Same as CSG14UP-24VDC model, except -48VDC input replaces 24VDC www GarrettCom com...
  • Page 24 Other Tray configurations with power supplies and power cabling included - See Section 3.3 DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one CSG14 Series Switch, See Section 3.4 Conformal Coating (for high humidity and “tropical” applications) - request quote. www GarrettCom com...
  • Page 25: Introduction

    This package should contain: Magnum CSG14 Series Converter Switch unit, External Power Supply, (for -Hd, -Hi, -Pd and -Pi models only) 1 set Metal panel mounting clips and screws (2 each) User Guide (this manual) www GarrettCom com...
  • Page 26: Product Description

    AC or DC input power selection and multiple application environments, and you have the Magnum CSG14 Converter Switch family. The Magnum CSG14 family of Converter Switches with a 1000Mb, 100Mb or 10Mb Fiber port built in covers the full range of application environments, with Hardened www GarrettCom com...
  • Page 27 8 to15V, 24V or -48V DC are included. The ambient temperature rating of –25 to 60C is for industrial use. No internal airflow is required for cooling, so it resists dust, dirt, moisture, smoke and insects. Mounting options include stand-alone panel mounting, DIN-Rail, or rack-mount tray. www GarrettCom com...
  • Page 28 Switch convenient and cost-effective for the user. The selection of various temperature ranges enables deployment in various industrial environments. And, it uses very little space. Providing the combination of Media Converter with Switch, the CSG14 Series is an ideal choice for edge-of–the-network applications. www GarrettCom com...
  • Page 29 CSG14H resist dust, dirt, moisture, smoke and insects. Choices of models for external AC or internal DC power are available. Ambient operating temperature is – 25°C to + 60°C depending on the power source used. Storage temperature rating is –40°C to + 100°C www GarrettCom com...
  • Page 30 DIN-rail, or rack-mount tray. Choices of models for external AC or internal DC power are available. Ambient operating temperature is between –40°C to +75°C depending on the power source used. Storage temperature rating is between –40°C to +100°C. www GarrettCom com...
  • Page 31 The single fiber port on the CSG14 is multi-mode with an SC connector or small form-factor connector (LC single-mode). The external DC power plug connector and/or “jack” and the internal DC input terminal is provided on the rear of the unit. www GarrettCom com...
  • Page 32: Csg14Uh / Csg14Up Product Description

    Hardened factory-floor and Premium-rated outdoor models. This selection of models and fiber port types offers the best price-to-value ratio for each user and installation. Where a Media www GarrettCom com...
  • Page 33 (-40 to 75C), typically located outdoors. The CSG14UP models are built with premium-grade extended temperature components, and use similar thermal techniques as the CSG14UH Hardened units. In addition to a Premium-rated AC power option and jack, www GarrettCom com...
  • Page 34 Switch convenient and cost-effective for the user. The selection of various temperature ranges enables deployment in various industrial environments. And, it uses very little space. Providing the combination of Media Converter with Switch, the CSG14U Series is an ideal choice for edge-of–the-network applications. www GarrettCom com...
  • Page 35 CSG14UH resist dust, dirt, moisture, smoke and insects. Choices of models for external AC or internal DC power are available. Ambient operating temperature is –25°C to + 60°C depending on the power source used. Storage temperature rating is –40°C to + 100°C www GarrettCom com...
  • Page 36 Mounting options include panel mounting, DIN-rail, or rack-mount tray. Choices of models for external AC or internal DC power are available. Ambient operating temperature is between –40°C to +75°C depending on the power source used. Storage temperature rating is between –40°C to +100°C. www GarrettCom com...
  • Page 37 The two fiber ports on the CSG14U are multi-mode or single-mode with a small form-factor connector (LC multi-mode or LC single-mode). The external DC power plug connector and/or “jack” and the internal DC input terminal is provided on the rear of the unit. www GarrettCom com...
  • Page 38: Frame Buffering And Latency

    Since collisions and bad packets are more likely when traffic is heavy, the result of store-and-forward operation is that more bandwidth is available for good packets when the traffic load is greatest. To minimize the possibility of dropping frames on congested ports, each www GarrettCom com...
  • Page 39 Then, normal packet buffering and processing resumes. This flow-control sequence occurs in a small fraction of a second and is transparent to an observer. See Section 4.6 for additional details. www GarrettCom com...
  • Page 40 For 10 Mb-to-10 Mb or 10 Mb-to-100Mb or 100Mb-to-10 Mb forwarding, the latency is 15 microseconds plus the packet time at 10 Mb. For 100Mb-to-100Mb forwarding, the latency is 5 microseconds plus the packet time at 100Mb. www GarrettCom com...
  • Page 41: Features And Benefits

    Choice of 10, 100 or 1000Mb Fiber option, more efficient than media converter Designed as a multi-purpose media converter and Switch, the 10, 100 or 1000Mb fiber port allows the user to convert the media from copper to fiber www GarrettCom com...
  • Page 42 (MC14- Tray) or wall-mounted. Rugged metal case, Industrial grade CSG14 Series have a robust design and are packaged in a rugged sheet metal enclosure to ensure high reliability and durability even when placed in industrial or outdoor applications. www GarrettCom com...
  • Page 43 Magnum MC14-TRAY. MDIX ports to eliminate cross-over cable while cascading All the Magnum CSG14 Series Switches are featured with MDIX (auto- cross), which easily allow cascading with other Switch Hubs or media converters, without using the cross-over cable. www GarrettCom com...
  • Page 44: Applications For Csg14 Series Converter Switches

    The Magnum CSG14Ps fit very well in high temperature locations experiencing a need to scale the LAN quickly and cost effectively. The CSG14Ps www GarrettCom com...
  • Page 45 The ruggedness of the CSG14P’s aluminum case and the high reliability of the design compliment the temperature-controlled packaging to provide an exceptional Ethernet product. www GarrettCom com...
  • Page 46 CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Example 1: Indoor Office CSG14H www GarrettCom com...
  • Page 47 This need can be easily met using the economical Magnum CSG14 Converter Switch. Additional functionality includes the ability to transfer data across large distances with multi- or single–mode fiber while securing the LAN from EMI and wire-tapping. www GarrettCom com...
  • Page 48 CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Example 2: CSG14H www GarrettCom com...
  • Page 49 Built with high-grade components, efficient cooling techniques and having no openings for dirt to enter, the CSG14 Series Converter Switches provide the very effective solution for this need. www GarrettCom com...
  • Page 50 CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) Example 3: CSG14P www GarrettCom com...
  • Page 51 Ethernet equipment such as motion detectors or will act as a test port for maintenance personnel with up-link for access to a central LAN and central file servers. www GarrettCom com...
  • Page 52 (for example, a pipeline). Such designs are easily extended or expanded as conditions and devices needing network attachment change over time. www GarrettCom com...
  • Page 53: Installation

    All the CSG14 Series Switches operate in transparent half-and full- duplex mode. The store and forward switch easily takes care of network traffic and can be used as a useful, economical tool to expand an existing network. www GarrettCom com...
  • Page 54 Make sure the unit is installed in a location that is easily accessible to an AC power outlet or the appropriate DC source and where cooling is not inhibited. The green Power (PWR) LED must turn ON when power is applied. www GarrettCom com...
  • Page 55: Mc14-Tray For Rack Mounting Of Csg14 Series Switches

    TRAY are specific to the Magnum products and will not permit other models to be properly mounted). In a typical installation, the MC14-TRAY, 19” rack-mount tray will hold a few (three to eight) CSG14 Series Converter Switches, www GarrettCom com...
  • Page 56: Mc14-Tr+Ps9 And Mc14-Tr+Ps9X2 For Rack Mounting Media Converters

    MC14-TR+PS9X2 are other options for rack mounting the mix of Magnum 10Mbps, 100Mbps and 1000Mbps Converter Switches and Media Converters together in a 19” rack-mount tray. These models come with a built-in common universal AC power supply rated at www GarrettCom com...
  • Page 57 MC’s are not used). Metal mounting screws in the bottom-front hold each of the media converters securing them in the tray and enabling separate removal for service. The dual LEDs permit viewing of Switch status from any angle. www GarrettCom com...
  • Page 58: Din-Rail Mounting Option

    “snap-on” attachment and removal. The Magnum CSG14 models with “HR” have 24VDC power, and have the DIN- Rail-MC2 bracket included and assembled with the MC unit at the factory. www GarrettCom com...
  • Page 59: Power Requirements For Csg14 Series Switches

    The CSG14 Series are designed to be used with UL listed Class II power supplies. The CSG14H and CSG14P converter switches provide reliable operation, withstand higher temperature environments, and provide the DC power choices to the user to deploy in uncontrolled temperature environments. 12VDC 24VDC -48VDC www GarrettCom com...
  • Page 60: Powering The Csg14 With 12V, 24V Or -48Vdc Power Input

    Three models support a range of power input types. The three model choices are for use with 12VDC, 24VDC or -48VDC power. DC power input may be chosen for high- availability. www GarrettCom com...
  • Page 61 DC Power Terminals: “+”, “-”, gnd GND: Terminal for “earth” or ground wire connection to the CSG14H chassis Input Voltage: 8 - 15V DC (12V DC) 18 – 36V DC (24V DC) 36 – 60V DC (-48V DC) www GarrettCom com...
  • Page 62: Csg14 Series, Dc-Powered, -48, 24 And 12Vdc Installation

    12VDC leads) to the DC power terminal block on the Magnum CSG14H hardened media converter (as shown in Figure). The DC terminal block on the Magnum CSG14H is located on the left side of the unit and is www GarrettCom com...
  • Page 63 +ve potential lead or -ve potential lead. The more +ve potential lead will connect to the post-labeled “+ve” and the rest to the “-ve”. The GND can be hooked up at the last. When power is applied, the green PWR LED will illuminate. www GarrettCom com...
  • Page 64: Connecting Ethernet Media

    9/125 microns cabling should be used. Fiber cabling supports much longer cable distance and higher bandwidths as compared to copper wiring. Media IEEE Standard Connector Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45 Twisted Pair (CAT 5) 100BASE-TX RJ-45 Twisted pair (CAT5E or CAT6) 1000BASE-T RJ-45 Fiber (Multi-mode) 10BASE-FL www GarrettCom com...
  • Page 65: Connecting Twisted Pair (Rj-45, Cat 3, Cat 5 Or Cat 6, Unshielded Or Shielded)

    Connecting Twisted Pair (RJ-45, CAT 3, CAT 5 or CAT 6, Unshielded or Shielded) The following procedure describes how to connect a 10BASE-T, 100BASE-TX or 1000BASE-T twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted pair cables. www GarrettCom com...
  • Page 66: Connecting Fiber Optic Lc-Type, "Small Form Factor (Sff)

    The following procedure applies to installations using LC-type fiber connectors, i.e., using LC single-mode. While connecting fiber media to LC connectors, simply snap on the two square male connectors into the LC female jacks of the Fiber connector until it clicks and secures. www GarrettCom com...
  • Page 67: Connecting Fiber Optic Sc-Type, "Snap-In

    Single-mode fiber allows full bandwidth at longer distances, about 70km with the single-mode LC. The same procedures as for single-mode fiber apply to multi-mode fiber connectors. Follow the steps listed in Section 3.8.3 above. www GarrettCom com...
  • Page 68: Power Budget Calculations For Csg14 Series, Fiber Media

    “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km The following data has been collected from component manufacturer’s (HP’s, and Siemens’) web sites and catalogs to provide guidance to network designers and installers www GarrettCom com...
  • Page 69 Single 1000Mb CSG14- -mode 1310 9/125 -9.5 10.5 LX10 1000Mb Single CSG14- 9/125 -4.0 37.5 17.5 1310 -mode LX25 Single 1000Mb CSG14- -mode 9/125 -4.0 17.5 1550 ZX40 Single 1000Mb CSG14- -mode 9/125 -3.0 20.5 1550 ZX70 www GarrettCom com...
  • Page 70: Connections To Nics Which Support Auto-Negotiation

    NIC has been communicating with a protocol other than 1000BASE-T (such as 100BASE-TX). When 1000Mb operation is agreed and in use, the Gb LED is illuminated steady ON and is OFF, for 10 or 100Mbps traffic. www GarrettCom com...
  • Page 71: Operation

    Magnum CSG14 Series units are plug-and-play devices. There is no software configuring to be done at installation or for maintenance. The only hardware configuration settings are user options for port #2, to configure it FF/AN. The internal functions of both are described below. www GarrettCom com...
  • Page 72 The Magnum CSG14 Series units have address table capacity of 1K node addresses, and are suitable for use in large networks. They are self-learning, so that as nodes are added or removed or moved from one segment to another, the CSG14 Series www GarrettCom com...
  • Page 73: Auto-Cross (Mdix), Auto-Negotiation And Speed-Sensing

    (except for legacy products, which do not have auto- negotiation and which go to the default state accordingly). The Magnum Switch advertises its capability for 10, 100 or 1000Mbps speed and F/H duplex mode, and the www GarrettCom com...
  • Page 74: Dual Leds, Top-Front And In End With Ports

    The Link ports are also represented by LA1, LA2, and LA3. (Steady On or steady Off indicates no Receive Activity). Steady ON for 1000Mb speed, OFF for 100Mb or 10Mb speed per port www GarrettCom com...
  • Page 75: Troubleshooting

    Magnum CSG14 Series 10/100/1000 Mb/s Switch is not performing as expected, do not attempt to repair the unit; instead contact your supplier for assistance or contact GarrettCom Customer Support. www GarrettCom com...
  • Page 76: Before Calling For Assistance

    If the problem is isolated to a network device other than the Magnum CSG14 Series 10/100/1000 Mb/s switch product, it is recommended that the problem device is replaced with a known good device. Verify whether or www GarrettCom com...
  • Page 77: When Calling For Assistance

    If the problem continues after completing Step 4 above, contact your supplier of the Magnum CSG14 Series 10/100/1000 Mb/s Switch unit or if unknown, contact GarrettCom, Inc by fax, phone or email (support@garrettcom.com) for assistance. 5.2 When Calling for Assistance Please be prepared to provide the following information.
  • Page 78 CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) An accurate list of GarrettCom product model(s)involved, with serial number(s). Include the date(s) that you purchased the products from your supplier. It is useful to include other network equipment models and related hardware, including convenient computers, workstations, terminals and printers;...
  • Page 79: Return Material Authorization (Rma) Procedure

    Name and phone number of your contact person. Name of your company / institution Your shipping address Product name Serial Number (or Invoice Number) Packing List Number (or Sales Order Number) Date of installation Failure symptoms, including a full description of the problem. www GarrettCom com...
  • Page 80 CSG14 Series Gigabit Converter Switch Installation and User Guide (12/08) GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete details).
  • Page 81: Shipping And Packaging Information

    Installation and User Guide (12/08) 5.4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions: 1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for shipping protection.
  • Page 82: Appendix A: Warranty Information

    GarrettCom, Inc. warrants its products to be free from defects in materials and workmanship for a period of three (3) years from the date of shipment by GarrettCom. During this warranty period, GarrettCom will repair or, at its option, replace components in the products that prove to be defective at no charge other than shipping and handling, provided that the product is returned pre-paid to GarrettCom.

Table of Contents