2.3.7 IRQ and Address Setting

The IRQ and I/O address range of COM3 and COM4 are listed below:
• COM3: 3E8
• COM4: 2E8
• Vector address for share IRQ: 1D0
You can set "Share IRQ" or "Independent IRQ" by the first switch of
SW4.
Table 2.2: IRQ Setting via switch 1 at SW4
Switch 1 at SW4 setting
You can adjust the transmission rate by the second switch of SW4.
Table 2.3: IRQ Setting via switch 1 at SW4
Switch 1 at SW4 setting
* To increase the normal baud rates by eight times, (e.g. if 115.2K bps is
set, the baud rate will be increased to 921.6K bps), set switch 2 of SW4
to "on".