Jumper Setting; Output Pulse [Cw±/Puls± And Cw±/Dir±] - Advantech MVP-3245 Series User Manual

4-axis embedded motion controller
Table of Contents

Advertisement

3.1.2

Jumper Setting

On the MVP-3245, CN24 (axis X), CN25 (axis Y), CN26 (axis Z), and CN27 (axis U)
can be configured via jumper settings.
The circuit shown in Figure 3.3 (with the first two rows of CN24-CN27 short-circuited)
is set to differential output mode as default.
To switch to single-ended output mode, simply change the jumper connector.
Change the output voltage of CW+/PULS+ and CCW+/DIR+ on the I/O connector's
pin of any axis to +5 V when the first two rows of CN24-CN27 are short-circuited.
Jumper Setting
3.1.3
Output Pulse [CW±/PULS± and CW±/DIR±]
There are two types of pulse command: clockwise/counterclockwise mode and pulse/
direction mode.
CW+/PULS+ and CW-/PULS- are differential signal pairs, as are CCW+/DIR+ and
CCW-/DIR-.
The default pulse output mode is pulse/direction. The output mode can be changed
by programming.
Description
Differential output mode
Single-ended output mode
Figure 3.2 Photocoupler Interface
19
MVP-3245 User Manual