Time Monitoring Feature; Figure 1.40 Switching Direction Of Transfer Over Data Bus - Fujitsu MBA3073 SERIES Technical Manual

Disk drives scsi physical interface specifications
Hide thumbs Also See for MBA3073 SERIES:
Table of Contents

Advertisement

1) The TARG negates the I/O signal.
2) The TARG releases the DB(15-0, P_CRCA and/or P1) within one System Deskew Delay.
3) The INIT detects the negation of the I/O signal.
4) The INIT asserts the DB(15-0, P_CRCA and/or P1) more than one System Deskew Delay.
f) The P_CRCA signal direction may switch direction while the DATA BUS and/or DB(P1)
does not (e.g., changing from COMMAND phase to DT DATA OUT phase).
When switching the P_CRCA signal direction from out (INIT driving) to in (TARG driving)
1) The TARG delays driving the P_CRCA by at least one Data Release Delay plus one
Bus Settle Delay after negating the C/D signal
2) The INIT releases the P_CRCA signal within one Data Release Delay after the
transition of the C/D signal to false.
When switching the P_CRCA signal direction from in (TARG driving) to out (INIT driving)
1) The TARG releases the P_CRCA signal within one System Deskew Delay after
asserting the C/D signal.
2) The INIT negates the P_CRCA signal more than one System Deskew Delay after the
detection of the assertion of the C/D signal.
g) The ATN and RST signals may change as defined under the descriptions for the attention
condition and hard reset.

Figure 1.40 Switching direction of transfer over data bus