Timing Rule; Timing Value; Table 1.15 Scsi Bus Control Timing Values - Fujitsu MBA3073 SERIES Technical Manual

Disk drives scsi physical interface specifications
Hide thumbs Also See for MBA3073 SERIES:
Table of Contents

Advertisement

Timing Rule

1.5.1

Timing value

Table 1.15, 16, 17 give the timing required for operations on the SCSI bus.
Timing description
1
Arbitration delay
2
Bus clear delay
3
Bus free delay
4
Bus set delay
5
Bus settle delay
6
Cable skew (1)
7
Data release delay
8
DIFFSENS voltage filter time
9
Physical disconnection delay
10
Power on to selection (2)
11
QAS arbitration delay
12
QAS assertion delay
13
QAS release delay
14
QAS non-DATA phase
REQ(ACK) peiod
15
Reset delay
16
Reset hold time
Note:
(1) Cable Skew is measured at each device connection with the transmitted skew subtracted from
the received skew. (2) This is a recommended time. It is not mandatory.
40
Table 1.15
SCSI bus control timing values
Type
Timing values
2.4 μs
Min
Max
800 ns
Min
800 ns
1.6 μs
Max
Min
400 ns
Max
4 ns
Max
400 ns
Min
100 ms
200 μs
Min
Max
10 s
Min
1000 ns
Max
200 ns
Max
200 ns
Min
50 ns
Min
200 ns
25 μs
Min
C141-C015

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mba3147 seriesMba3300 nc seriesseries

Table of Contents