Removal Of Compressor - Daikin FTXS30HVJU Service Manual

Inverter pair wall mounted type h-series
Hide thumbs Also See for FTXS30HVJU:
Table of Contents

Advertisement

SiUS04-924
2.7

Removal of Compressor

Procedure
Step
1
Remove the terminal
cover.
2
Pull out the 3 leads
using long-nose pliers.
3
Remove the OL.
180
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembly work.
Procedure
U(red)
V(yellow)
OL
(R9650)
 U:red, V:yellow, W:blue
W(blue)
(R9471)
Outdoor Unit
Points
Removal Procedure

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ftxs36hvjuRxs30hvjuRxs36hvju

Table of Contents