SiUS04-924
2.3
Removal of PCB
Procedure
Step
Remove the electrical box
before hand.
1
Remove the cover.
2
Disconnect the
connectors of the
service monitor PCB for
the control PCB [S52,
S102].
3
Release the 4 clamps
with pliers.
170
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembly work.
Procedure
[
[
]
Service monitor PCB
(R9611)
]
(R9629)
Outdoor Unit
Points
Removal Procedure