Indoor Unit; Removal Of Air Filter / Front Panel - Daikin FTXS30HVJU Service Manual

Inverter pair wall mounted type h-series
Hide thumbs Also See for FTXS30HVJU:
Table of Contents

Advertisement

SiUS04-924

1. Indoor Unit

1.1

Removal of Air Filter / Front Panel

Procedure
Step
1. External appearance
2. Removal of the air filters.
1
Hold the front panel by
the tabs on the both
sides and lift it until it
stops with a click.
2
Lift an air filter upwards
slightly by the center
knob, and then pull it out
downwards.
114
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembly work.
Procedure
Signal receiver
Timer lamp
ON/OFF switch
Air filter
(R9473)
Operation lamp
INVERTER
INTELLIGENT
EYE sensor
ON/OFF
INTELLIGENT
EYE lamp
Room temperature sensor
(thermistor)
(R9474)
Front Panel
(R9475)
Hooks
(R9476)

Indoor Unit

Points
 When the signal receiver
catches a signal from the
remote controller, it produces
beep sound and the operation
lamp blinks.
 The 3 filters are
interchangeable.
 Set the air filters with
displaying "FRONT" on the
front side.
 Set the air filters on the hooks
of the front grille ASSY.
Removal Procedure

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ftxs36hvjuRxs30hvjuRxs36hvju