Indoor Unit
1.4

Removal of PCB

Procedure
Step
1. Removal the control PCB.
1
Cut the clamp.
2
Release the harness
from the hook.
3
Push and release the
hook.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembly work.
Procedure
Clamp
Points
(R9513)
 When reassembling, make
sure to hook the wiring.
(R9514)
(R9515)