Installing The Server Into A Telco Rack - Supero SUPERSERVER 1026T-URF User Manual

Superserver 1026t-urf superserver 1026t-uf
Table of Contents

Advertisement

Warning! To prevent bodily injury when mounting or servicing this unit in a
rack, you must take special precautions to ensure that the system remains
stable. The following guidelines are provided to ensure your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
When mounting this unit in a partially fi lled rack, load the rack from the bottom
to the top with the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.

Installing the Server into a Telco Rack

To install the SuperServer 1026T-URF/1026T-UF into a Telco type rack, use two
L-shaped brackets on either side of the chassis (four total). First, determine how
far follow the server will extend out the front of the rack. Larger chassis should be
positioned to balance the weight between front and back. If a bezel is included on
your server, remove it. Then attach the two front brackets to each side of the chas-
sis, then the two rear brackets positioned with just enough space to accommodate
the width of the telco rack. Finish by sliding the chassis into the rack and tightening
the brackets to the rack.
Chapter 2: Server Installation
2-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Superserver 1026t-uf

Table of Contents