Outer Rails

Installing the Outer Rails to the Rack (Figures 2-3 and 2-4)
1. Attach the short bracket to the outside of the long bracket. You must align the
pins with the slides. Also, both bracket ends must face the same direction.
2. Adjust both the short and long brackets to the proper distance so that the rail
fi ts snugly into the rack.
3. Secure the long bracket to the front side of the outer rail with two M5 screws
and the short bracket to the rear side of the outer rail with three M5 screws.
4. Repeat steps 1-4 for the left outer rail.
Figure 2-3. Assembling the Outer Rails
Secure to the
Front of the Rack
Warning: do not pick up the server with the front handles. They are de-
signed to pull the system from a rack only.
Warning! Stability hazard. The rack stabilizing mechanism must be in
place, or the rack must be bolted to the fl oor before you slide the unit out
for servicing. Failure to stabilize the rack can cause the rack to tip over.
Attach Outer Racks
Together
2-6
Secure to the
Rear of the Rack