Supero SUPERSERVER 1026T-URF User Manual page 116

Superserver 1026t-urf superserver 1026t-uf
Table of Contents

Advertisement

S
S
UPER
ERVER 1026T-URF/1026T-UF User's Manual
Chassis
1026T-URF: SC113TQ-R650 (1U rackmount form factor)
1026T-UF: SC113TQ-560 (1U rackmount form factor)
Dimensions (both): (WxHxD) 17.2 x 1.7 x 23.5 in. (437 x 43 x 597 mm)
Weight
Gross (Bare Bone): 33 lbs. (15 kg.)
System Cooling
Four 4-cm counter-rotating fans
System Input Requirements
AC Input Voltage: 100-240 VAC
Rated Input Current: 8A (115V) to 4A (230V)
Rated Input Frequency: 50-60 Hz
Power Supply
1026T-URF
Rated Output Power: 650W (Model# PWS-651-1R)
Rated Output Voltages: +5V (25A), +3.3V (12A), +12V (54A), +5Vsb (3A)
1026T-UF
Rated Output Power: 560W (Model# PWS-562-1H20)
Rated Output Voltages: +5V (20A), +3.3V (20A), +12V (46.5A), -12V (0.5A),
+5Vsb (4A)
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-
3-3, CISPR 22 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-
4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-
4-11)
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and
Canada), CE Marking (Europe)