Commands Set - Advantech EKI-7556MI User Manual

16+2 100fx port managed redundant industrial ethernet switch (wide temp.)
Table of Contents

Advertisement

Commands
monitor rx
monitor tx
show monitor
monitor
[RX|TX|Both]
show monitor
no monitor
3.2.13
802.1x Commands Set
Table 3.13: 802.1x Commands Set
Commands
8021x enable
8021x system radiusip
[IP address]
8021x system serverport
[port ID]
8021x system accountport
[port ID]
8021x system sharekey
[ID]
8021x system nasid
[words]
8021x misc quietperiod
[sec.]
8021x misc txperiod
[sec.]
8021x misc supportimeout
8021x misc servertimeout
8021x misc maxrequest
[number]
8021x misc reauthperiod
[sec.]
8021x portstate
[disable | reject | accept | authorize]
show 8021x
EKI-7556MI_Manual
Level
Set RX destination port of monitor
G
function
Set TX destination port of monitor
function
G
Show port monitor information
P
Configure source port of monitor
I
function
Show port monitor information
I
Disable source port of monitor
I
function
Level
Use the 802.1x global
G
configuration command to enable
802.1x protocols.
Use the 802.1x system radius IP
global configuration command to
G
change the radius server IP.
Use the 802.1x system server port
global configuration command to
G
change the radius server port
Use the 802.1x system account
port global configuration command
G
to change the accounting port
Use the 802.1x system share key
global configuration command to
G
change the shared key value.
Use the 802.1x system nasid
global configuration command to
G
change the NAS ID
Use the 802.1x misc quiet period
global configuration command to
G
specify the quiet period value of
the switch.
Use the 802.1x misc TX period
global configuration command to
G
set the TX period.
Use the 802.1x misc supp timeout
[sec.]
global configuration command to
G
set the supplicant timeout.
Use the 802.1x misc server
[sec.]
timeout global configuration
G
command to set the server
timeout.
Use the 802.1x misc max request
global configuration command to
G
set the MAX requests.
Use the 802.1x misc reauth period
global configuration command to
G
set the reauth period.
Use the 802.1x port state interface
configuration command to set the
I
state of the selected port.
Displays a summary of the 802.1x
E
properties and also the port sates.
Description
switch(config)#monitor rx
switch(config)#monitor tx
switch#show monitor
switch(config)#interface fastEthernet 2
switch(config-if)#monitor RX
switch(config)#interface fastEthernet 2
switch(config-if)#show monitor
switch(config)#interface fastEthernet 2
switch(config-if)#no monitor
Description
switch(config)# 8021x enable
switch(config)# 8021x system radiusip 192.168.1.1
switch(config)# 8021x system serverport 1815
switch(config)# 8021x system accountport 1816
switch(config)# 8021x system sharekey 123456
switch(config)# 8021x system nasid test1
switch(config)# 8021x misc quietperiod 10
switch(config)# 8021x misc txperiod 5
switch(config)# 8021x misc supportimeout 20
switch(config)#8021x misc servertimeout 20
switch(config)# 8021x misc maxrequest 3
switch(config)# 8021x misc reauthperiod 3000
switch(config)#interface fastethernet 3
switch(config-if)#8021x portstate accept
switch>show 8021x
42
Example
Example

Advertisement