2. While the telephone is attempting to contact the SCEP server and to obtain a certificate, the
Title Line displays:
SCEP: In progress...
s secs
where s is the number of seconds since SCEP was initiated/
3. If the initial attempt to contact the SCEP server is not successful the telephone continues
with start-up, and will not try to contact the SCEP server again unless it is reset or
power-cycled.
4. If a connection to the SCEP server is successfully established, if the value of the
configuration parameter MYCERTWAIT is 1, SCEP remains in progress until the request for
a certificate is granted or rejected.
5. If the request for a certificate is granted, SCEP: Successful displays on the Title line for at
least one second, and remains until it is replaced by a subsequent display.
6. The SCEP server connection terminates, and the telephone continues with start-up. If the
request for a certificate is rejected SCEP: Failed displays on the Title line for at least one
second, and remains until it is replaced by a subsequent display. In this case, the SCEP
server connection terminates and the telephone continues with startup.
7. if the value of the configuration parameter MYCERTWAIT is 0 (zero), SCEP remains in
progress until the request for a certificate is granted or rejected or until a response is
received indicating that the request is pending for manual approval. If the request for a
certificate is granted or rejected, the same text will be displayed as specified above.
8. If a response is received indicating that the request is pending for manual approval, SCEP:
Pending displays on the Title line for at least one second and remains until it is replaced by
a subsequent display. The connection to the SCEP server is terminated, and the telephone
continues with startup. The telephone periodically attempts to contact MYCERTURL as
specified above (but in the background without displaying any message) until the request is
granted or rejected.
9. If a device certificate and private key are successfully downloaded, they are saved in
non-volatile memory along with the MYCERTURL value used to obtain them.
10. When the point in time is reached at which the percentage of the interval of time specified in
the device certificate's Validity object corresponding to the value of the configuration
parameter MYCERTRENEW has elapsed, the telephone periodically attempts to contact
MYCERTURL as specified above (but in the background without displaying any message)
to renew the certificate, until the renewal request is granted or rejected.