User Interfaces
The Terminal Control Mode is menu-driven and the allowable values for each item number will be
shown. To change an item, type in its number followed by <ENTER>. If the parameter to be
changed requires a numeric value, enter the number followed by <ENTER> If the parameter is
non-numeric, press <SPACE> to cycle through the list of available entries.
Items that do not have ID numbers are Status only and cannot be
changed.

4.6 Connecting the Terminal

1.
Connect the computer to the Remote Connector (J20) on the rear of the unit
using the RS-232 Cable.
2.
Enable the terminal by selecting Terminal Mode (located under the System -
Control Mode Menu) from the front panel.
3.
Verify that your emulation software is set to the following:
8 data bits
no parity
1 stop bit
Modify the selection, if necessary, to match the settings (the Front Panel
'SYSTEM' Sub-Menu contains all the Terminal Emulation Controls).

4.7 Terminal Screens

For terminal screens, refer to the DMD50 Remote Protocol Manual TM-117.

4.8 RS485 Remote Port Interface (RLLP Protocol)

The Remote Port allows for complete control and monitoring of all parameters and functions via
an RS-232 Serial Interface or RS-485 utilizing RLLP Protocol. 'Equipment Remote Mode' can be
entered from the GUI interface under the "System" menu by selecting "System" and then
"Terminal" followed by "Terminal". The baud rate and evaluation type can be changed at the front
panel by using the System>Baud Rate Menu.
4-42
DMD50 Universal Satellite Modem