AXIS A1001 Network Door Controller & AXIS Entry Manager
Hardware Overview
Lock
Green
Red
Unlit
Note
• The Status LED can be configured to flash while an event is active.
• The Status LED can be configured to flash for identifying the unit. Go to Setup > Additional Controller Configuration >
System Options > Maintenance .

Connectors and Buttons

For technical specifications, see page 45.
I/O Interface
Reader Data Connector
Two 6-pin terminal blocks supporting RS485 and Wiegand protocols for communication with the reader.
Reader I/O Connector
Two 6-pin terminal blocks for reader input and output. In addition to the 0 V DC reference point and power (DC output), the
reader I/O connector provides the interface to:
Digital input – For connecting, for example, reader tampering alarms.
Digital output – For connecting, for example, reader beepers and reader LEDs.
Door Connector
Two 4-pin terminal blocks for connecting door monitoring devices and request to exit (REX) devices
Auxiliary Connector
4-pin configurable I/O terminal block. Use with external devices, in combination with, for example tampering alarms, event triggering
and alarm notifications. In addition to the 0 V DC reference point and power (DC output), the auxiliary connector provides the
interface to:
Digital input – An alarm input for connecting devices that can toggle between an open and closed circuit, for example PIR
sensors or glass break detectors.
Digital output – For connecting external devices such as burglar alarms, sirens or lights. Connected devices can be
activated by the VAPIX® application programming interface or by an action rule.
External Power Inputs
NOTICE
NOTICE
NOTICE
The product shall be connected using a shielded network cable (STP). All cables connecting the product to the network shall
be intended for their specific use. Make sure that the network devices are installed in accordance with the manufacturer's
instructions. For information about regulatory requirements, see Electromagnetic Compatibility (EMC), on page 2 .
Power Connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either
a rated output power limited to ≤100 W or a rated output current limited to ≤5 A.
Network Connector
RJ45 Ethernet connector. Supports Power over Ethernet (PoE).
Power Outputs
Power Lock Connector
4-pin terminal block for connecting one or two locks. The lock connector can also be used to power external devices.
Steady when not energized.
Steady when energized.
Floating.