Axis A1001 User Manual page 51

Network door controller & entry manager
Hide thumbs Also See for A1001:
Table of Contents

Advertisement

AXIS A1001 Network Door Controller & AXIS Entry Manager
Technical Specifications
Function
Power and Ethernet
Power Lock Connector
4-pin terminal block for powering one or two locks (DC output). The lock connector can also
be used to power external devices.
Connect locks and loads to the pins according to the hardware pin chart generated through
the hardware configuration.
Function
0 V DC (-)
0 V DC, floating, or
12 V DC
Power & Relay Connector
6-pin terminal block with built-in relay for:
• External devices
• Auxiliary power (DC output)
• 0 V DC (-)
Connect locks and loads to the pins according to the hardware pin chart generated through
the hardware configuration.
Function
0 V DC (-)
Relay
12 V DC
Tampering Alarm Pin Header
Two 2-pin headers for bypassing:
• Back tampering alarm (TB)
• Front tampering alarm (TF)
Function
Back tampering alarm
Front tampering alarm
Specifications
Power over Ethernet IEEE 802.3af/802.3at Type 1 Class 3
Max load on outputs = 7.5 W
Pin
Notes
1, 3
2, 4
For controlling up to two 12 V locks. Use the hardware
pin chart. See Configure the Hardware, on page 11.
Pin
Notes
1, 4
2–3
For connecting relay devices. Use the hardware pin
chart. See Configure the Hardware, on page 11.
The two relay pins are galvanically separated from the
rest of the circuitry.
5
For powering auxiliary equipment.
Note: This pin can only be used as power out.
Pin
1–2
1–2
Notes
To bypass the front and back tampering alarm simultaneously, connect jumpers
between TB 1, TB 2 and TF 1, TF 2 respectively.
51
Specifications
0 V DC
12 V DC
Max total load = 500 mA
Specifications
0 V DC
Max current = 700 mA
Max voltage = +30 V DC
Max voltage = +12 V DC
Max load = 500 mA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Axis a1001