Advanced; Scripting/File Upload; Reset To Factory Default Settings - Axis A1001 User Manual

Network door controller & entry manager
Hide thumbs Also See for A1001:
Table of Contents

Advertisement

AXIS A1001 Network Door Controller & AXIS Entry Manager
System Options

Advanced

Scripting
Scripting allows experienced users to customize and use their own scripts.
NOTICE
NOTICE
NOTICE
Improper use may cause unexpected behavior and loss of contact with the Axis product.
Axis strongly recommends that you do not use this function unless you understand the consequences. Axis Support does not provide
assistance for problems with customized scripts.
To open the Script Editor, go to Setup > Additional Controller Configuration > System Options > Advanced > Scripting. If a
script causes problems, reset the product to its factory default settings, see page 41.
For more information, see www.axis.com/developer
File Upload
Files, for example web pages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go to
Setup > Additional Controller Configuration > System Options > Advanced > File Upload.
Uploaded files are accessed through http://<ip address>/local/<user>/<file name> where <user> is the
selected user group (viewer, operator or administrator) for the uploaded file.

Reset to Factory Default Settings

Important
Reset to factory default should be used with caution. A reset to factory default will reset all settings, including the IP
address, to the factory default values.
Note
The installation and management software tools are available from the support pages on www.axis.com/techsup
To reset the product to the factory default settings:
1. Disconnect power from the product.
2. Press and hold the control button and reconnect power. See Hardware Overview, on page 5 .
3. Keep the control button pressed for about 25 seconds until the status LED indicator turns amber for the second time.
4. Release the control button. The process is complete when the status LED indicator turns green. The product has been reset
to the factory default settings. If no DHCP server is available on the network, the default IP address is 192.168.0.90
5. Using the installation and management software tools, assign an IP address, set the password and access the video stream.
It is also possible to reset parameters to factory default via the web interface. Go to Setup > Additional Controller Configuration >
Setup > System Options > Maintenance.
41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Axis a1001

Table of Contents