AXIS A1001 Network Door Controller & AXIS Entry Manager
Alarm and Event Configuration
Log alarm for selected controllers – Enable alarm logging in selected door controllers. The event will trigger an alarm
and be included in the alarm log.
In the Configure alarm logging list, click Select controllers under the alarm log item you want to enable. The Device
Specific Alarm Triggering dialog opens. Under Trigger alarm, select the door controllers that shall have alarm logging
enabled and click Save.

Events

The Axis product can be configured to perform actions when different events occur. For example, the product can send an email
notification when an alarm is triggered. The set of conditions that defines how and when the action is triggered is called an Action
Rule. For information about how to set up an action rule, see Setting Up an Action Rule, on page 29.
Available action rule triggers and conditions include:
Access Point
Access Point Enabled – Triggers the action rule when an access point device, for example a reader or REX
-
device, has successfully been installed and configured. This can for example be used to send a notification when
someone has installed or replaced an access point device.
Configuration
Access Point Changed – Triggers the action rule when the configuration settings of an access point device,
-
for example a reader or REX device, are changed. This can for example be used to send a notification when
someone has reconfigured an access point device.
-
Access Point Removed – Triggers the action rule when an access point device, for example a reader or REX
device, is removed from the system. This can for example be used to send a notification when someone has
removed and access point device.
-
Area Changed – Not supported by this version of AXIS Entry Manager. Must be configured by a client such as an
access management system, through the VAPIX® application programming interface, that supports this feature
and use devices that can provide the required signals. Triggers the action rule when an access area has changed.
-
Area Removed – Not supported by this version of AXIS Entry Manager. Must be configured by a client such
as an access management system, through the VAPIX® application programming interface, that supports this
feature and use devices that can provide the required signals. Triggers the action rule when an access area has
been removed from the system.
-
Door Changed – Triggers the action rule when the door configuration settings, for example door name, are
changed or when a door is added to the system. This can for example be used to send a notification when
someone has installed and configured a door.
-
Door Removed – Triggers the action rule when a door is removed from the system. This can for example be used
to send a notification when someone has removed a door from system.
Door
-
Door Alarm – Triggers the action rule when the door monitor indicates that the door has been forced open, the
door is open too long, or if the door is faulty in any way. This can for example be used to send a notification
when someone has forced an entry.
-
Door Double-Lock Monitor – Triggers the action rule only when the secondary lock changes state to either
locked or unlocked.
-
Door Lock Monitor – Triggers the action rule when the normal lock changes state to either locked or unlocked.
For example, a fault is triggered when the door monitor detects that the door is open although the lock is locked.
-
Door Mode – Triggers the action rule when the door changes states, for example, when the door has been
accessed or blocked, or the door is in lockdown mode. For more detailed descriptions of these modes, see the
online help.