AXIS A1001 Network Door Controller & AXIS Entry Manager
Alarm and Event Configuration
-
Door Monitor – Triggers the action rule when the door monitor state changes. This can for example be used to
send a notification when a door monitor indicates that the door is opened or closed.
-
Door Warning – Triggers the action rule before the door open too long alarm goes off. This can be used to,
for example, send a warning signal that the door controller will send the real alarm, the door open too long
alarm, if the door is not closed within the specified door open too long time. For more information about door
open too long time, see Locks, on page 12.
Event Logger
-
Alarm – Triggers the action rule when one of the specified alarms has been triggered. The system administrator
can configure which events are more important than others and select whether a particular event should
trigger an alarm or not.
Hardware
-
Casing Open – Triggers the action rule if the cover of the door controller is opened or if the door controller is
removed from the wall or ceiling. This can for example be used to send a notification if the casing has been
opened for maintenance purposes or when someone has tampered with the casing.
-
Network – Triggers the action rule when the network connection is lost. Select Yes to trigger the action
rule when the network connection is lost. Select No to trigger the action rule when the network connection
is restored.
Peer Connection – Triggers the action rule when the Axis product has established a connection with another
-
door controller, if the network connection between the devices is lost, or if the pairing of door controllers has
failed. This can for example be used to send a notification that a door controller has lost its network connection.
Input Signal
Digital Input Port – Trigger the rule when an I/O port receives a signal from a connected device. See I/O
-
Ports, on page 39.
Manual Trigger – Triggers the action rule when the manual trigger is activated. It can be used by a client such
-
as an access management system, through the VAPIX® application programming interface, to manually start
or stop the action rule.
Virtual Inputs – Triggers the action rule when one of the virtual inputs changes states. It can be used by a
-
client such as an access management system, through the VAPIX® application programming interface, to trigger
actions. Virtual inputs can, for example, be connected to buttons in the management system's user interface.
Schedule
Interval – Triggers the action rule when a one-time event occurs.
-
Pulse – Triggers the action rule when a recurring pulse schedule event occurs. This can be used for to send a
-
notification for a meeting that is scheduled to occur every Friday.
System
-
System Ready – Triggers the action rule when the system is in state ready. For example, the Axis product can
detect the system state and send a notification when the system has started.
Select Yes to trigger the action rule when the product is in state ready. Note that the rule will only trigger when
all necessary services, such as the event system, has started.
Time
-
Recurrence – Triggers the action rule by monitoring the recurrences that you have created. You can use this
trigger to initiate recurring actions such as sending notifications every 1 hour. Select a recurrence pattern or
create a new one. For more information about setting up a recurrence pattern, see Recurrences, on page 30.
-
Use Schedule – Trigger the rule according to the selected schedule. See Schedules, on page 30.
Available actions include:
28

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Axis a1001

Table of Contents