AXIS A1001 Network Door Controller & AXIS Entry Manager
System Configuration
-
Locked = Relay closed – Select for locks that unlock during power outages (fail open/safe).
None – Select if only one lock will be used.
Note
• Most lock, door monitor, and reader options can be changed without resetting and starting a new hardware configuration.
Go to Setup > Hardware Reconfiguration.
• Motorized locks must be configured as secondary locks.
Readers
1. If a reader will be used, select Reader and then select the options that match the reader's communication protocol.
2. If a request to exit (REX) device such as a button, sensor, or push bar will be used, select REX and then select the option
that matches how the REX device's circuits will be connected.
If the door shall remain locked until the user manually unlocks and opens the door, select Require manual unlock.
3. If connecting more than one reader or REX device to the door controller, do the previous two steps again until each
reader or REX device has the correct settings.
The following options for readers are available:
Wiegand – Select for readers that use Wiegand protocols.
RS485 half duplex – Select for RS485 readers with half duplex support and then select the RS485 protocol that is
supported by the reader. See the manufacturer's information about which protocol the reader supports.
RS485 full duplex – Select for RS485 readers with full duplex support and then select the RS485 protocol that is supported
by the reader. See the manufacturer's information about which protocol the reader supports.
The following options for REX devices are available:
Active low – Select if activating the REX device closes the circuit.
Active high – Select if activating the REX device opens the circuit.
Require manual unlock – Select if the door shall remain locked until the user manually unlocks and opens the door. The
door forced open alarm will not be triggered as long as the user opens the door within the access time. Deselect if the door
shall unlock automatically when the user activates the REX device.
Important
If the door controller has only been configured with one door before it is upgraded to firmware 1.15 or later from firmware
1.10, Require manual unlock will be non-selectable at first . To make Require manual unlock selectable, go to Setup >
Hardware Configuration and click Reset and start a new hardware configuration. Then set up the rules for the doors
connected to the door controller and add them to groups, see Doors.
Note
Most lock, door monitor, and reader options can be changed without resetting and starting a new hardware configuration.
Go to Setup > Hardware Reconfiguration.
Verify the Hardware Connections
When the hardware installation and configuration is complete, and anytime during the door controller's lifetime, you can verify the
function of the connected door monitors, locks and readers.
To verify the configuration and access the verification controls, go to Setup > Hardware Connection Verification.
Verification Controls
Door state –Verify the current state of the door monitor, door alarms and locks. Click Get current state.