Technical Specifications; Axis A1001 Network Door Controller - Axis A1001 User Manual

Network door controller & entry manager
Hide thumbs Also See for A1001:
Table of Contents

Advertisement

AXIS A1001 Network Door Controller & AXIS Entry Manager

Technical Specifications

Technical Specifications

AXIS A1001 Network Door Controller

Item
Function/group
Models
Door controller
Readers
Doors
Credentials
Event history
Access schedules
Digital I/O
I/O interface
I/O functionality
Network
Security
Supported protocols
System
Application
Integration
Programming Interface
Events & Alarms
Tamper detection
Event log
Event actions
Event triggers
Specifications
AXIS A1001 Network Door Controller
Up to 2 readers per controller (Wiegand, RS485 (OSDP)) with supported card formats
1
1–2 doors per controller
Up to 15 000 with third-party access management software depending on server
capacity
30 000 First in First out (FIFO) per controller
Unlimited or third-party software dependent
Reader I/0: DC output: 2x 12 V DC output max 300 mA; 2x 4 configurable
inputs/outputs, (digital input: 0 to max 40 V DC, digital output: 0 to max 40 V DC,
open drain, max 100 mA)
Reader data: RS485 full duplex, RS485 half duplex, Wiegand
Auxiliary: 1x 3.3 V DC output, max 100 mA, 2x configurable inputs/output (digital
input: 0 to max 40 V DC, digital output: 0 to max 40 V DC, open drain, max 100 mA)
Door connectors: 2x 2 input for door monitors and REX (digital input: 0 to
max 40 V DC)
Preconfigured for readers and door monitors, Input trigger, Output toggle/pulse
Password protection, IP address filtering, HTTPS
access control, digest authentication, user access log
2
IPv4, HTTP, HTTPS
, SSL/TLS
SNMPv1/v2c/v3(MIB-II), DNS, DynDNS, NTP, RTSP, RTP, TCP, UDP, IGMP, RTCP,
ICMP, DHCP, ARP, SOCKS
Open API for software integration, including VAPIX®; specifications available at
www.axis.com
ONVIF Profile C, specifications available at www.onvif.org
Support for access control as a service with One-Click Connection
Removal of unit cover/tamper front
Removal of unit from wall/tamper back
Reader tamper
Configurable by time and topic, Alarm acknowledgement
Notification via email, HTTP and TCP, External output port, Status LED
Access Point: Access point enabled
Configuration: Access point changed, Access point removed, Area changed, Area
removed, Door changed, Door removed
Door: Door alarm, Door double-lock monitor, Door lock monitor, Door mode, Door
monitor, Door warning
Event Logger: Alarm
Hardware: Casing open, Network, peer connection
Input Signal Digital input port, Manual trigger, Virtual inputs
Schedule: Interval, Pulse
System: System ready
Time: Recurrence, Use schedule
45
2
encryption, IEEE 802.1X network
2
, QoS layer 3 DiffServ, FTP, SMTP, Bonjour, UPnP,

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Axis a1001

Table of Contents