Flue installation

Flue kit

16
This heater is a flued appliance. It must be properly connected to a
flue system in accordance with the latest edition of the Gas Installa-
tion Code, AS 5601/AG 601.
If elbows are needed, the total horizontal length depends on the
number of elbows used. Venting should never slope down. A 6mm
per 500mm horizontal rise is recommended.
If practical locate the heater in a position to minimise the use of
horizontals and elbows.
20
The flue rise should be a minimum of 1.8m before any horizontal
run is used.
If placed against a combustible wall the 40mm rear spacers locate
against the wall.
1. Ensure clearances to combustible have been observed. For clear-
ances refer page 10.
2. The centre line of the flue is 120mm to rear of appliance (includ-
ing rear spacers).
3. Carry out installation as per figure 26 (ceiling plate installation)
and figure 27 (flue installation).
Cut a hole 180mm ø in the ceiling in line with the flue position.
Secure ceiling plate against the ceiling by bending out the tabs
above the ceiling.
Note: If the ceiling has an incline, the ceiling box will need to
be fitted. Installation instructions are supplied with the ceiling
box.
26
The flue kit contains:
3 x 900mm lengths of 125mm ø painted flue.
1 x 900mm length of 125mm ø plain flue.
1 x ceiling plate
1 x 900mm painted bottom flue spigot.