Installing the Server into the Rack
Installing the Chassis into a Rack (Figure 2-3)
1. Confi rm that chassis includes the inner rails and rail extensions . Also, confi rm
that the outer rails are installed on the rack.
2. Line chassis rails with the front of the rack rails.
3. Slide the chassis rails into the rack rails, keeping the pressure even on both
sides (you may have to depress the locking tabs when inserting). When the
server has been pushed completely into the rack, you should hear the locking
tabs "click".
4. (Optional) Insert and tightening the thumbscrews that hold the front of the
server to the rack.

Installing the Server into a Telco Rack

To install the 6017R-N3RF4+/6017R-N3RFT+ into a Telco type rack, use two L-
shaped brackets on either side of the chassis (four total). First, determine how far
follow the server will extend out the front of the rack. Larger chassis should be
positioned to balance the weight between front and back. If a bezel is included on
your server, remove it. Then attach the two front brackets to each side of the chas-
sis, then the two rear brackets positioned with just enough space to accommodate
the width of the telco rack. Finish by sliding the chassis into the rack and tightening
the brackets to the rack.
2-6