1 The ASSIGN KEYS are used to change settings between INPUT
VCA FOH (VCA MON if held for 3s), MUTE FOH (MUTE
MON if held for 3s) , AUDIO GROUP or AUX assignment in
conjunction with the SET switch on each channel.
Mute/
mon
Group
mute
(hold
3secs)
mon
mute
v.c.a./
aux /
vca
check
(hold
3secs)
1
2
3
4
5
6
7
8
9
10
11
12
Assigning Functions
lock
s-i-p
active system
(hold 3secs)
a
b
store
midi
system
insert
delete copy
check
cancel
confirm
act
scene
act/scene
up
down
c/o
last
now
next
monitor
MUTE
10
5
MUTE
0
f.o.h.
5
10
10
20
30
40
5
50
dB
0
5
1
2
3
10
4
5
15
6
7
20
8
9
30
10
40
SET
2 To un-lock the assignment function first press the LOCK
switch so that the LED is off.
3 The VCA FOH ,MUTE FOH, GROUP and AUX switches
set the assignment mode for the input modules. As default
these switches interlock so that only one mode can be
viewed at a time, however if they are pressed down for
more than 0.5 second the interlock is removed. This is used
for the "clear mode" (see below).
To access VCA and MUTE assignment to the MON signal
path press and hold either the FOH VCA or MON buttons
for 3 seconds. Instead of being constantly on the indicator
LED will flash to show that the MON path assignment has
now been selected.
4 Press the switches to assign the setup required. A long press
will allow multiple assignment of more than one
VCA/Aux/Group or Mute. A short press will clear the
previous settings.
In this mode (with all LED's off), operating an input SET
switch with a long press will clear all assignments. The
mode switches can be used to select which parts are
cleared, i.e. press VCA mode to clear VCAs, press GROUP
mode to clear routing, or use a long press to activate more
modes for simultaneous clearing.
5 Press the SET switch on the input channels for which the
assignments are required. The SET switch works in two
different ways. A long press will replace all previous
settings with the new assignments selected on the
assignment section. A short press will toggle between the
original and the new assignments. If the function is
assigned on both the input and the assignment section
pressing the SET button will switch that function on and
off.
6 To enter CLEAR mode set all the assign keys to off. To do
this simply press the ones that are illuminated which then
will toggle them off. Then press the SET keys on the
channel that need no assignment.