Assigning Vca's To Mon Signal Path - Midas LEGEND 3000 Operator's Manual

Table of Contents

Advertisement

Assigning VCA's To The MON Signal Path
Mute/
mon
Group
lock
s-i-p
mute
(hold
active system
3secs)
(hold 3secs)
mon
mute
v.c.a./
aux /
store
midi
system
vca
check
(hold
3secs)
insert
delete copy
1
2
check
cancel
confirm
3
4
5
6
act
scene
7
8
act/scene
down
c/o
9
10
last
now
next
11
12
2 To enter ASSIGNMENT mode first press the LOCK switch (to
a
un-lock the assignment system). So that the LED is off.
b
3 To assign a VCA to the MON signal path you must first press and
hold the VCA button so that its LED is flashing. This
indicates that the 10 LED's on the input channel now
indicate assignment of VCA's to the Monitor signal path.
4 Enable the switches to assign the set up required. A long press will
allow multiple assignments and a short press will clear the
previous assignments.
up
5 Press the SET switch on the input channels for which the
assignments are required. The SET switch works in two different
ways. A long press will replace all previous settings with the new
assignments, a short press will toggle between the original and the
new assignments.
6 To enter CLEAR mode set all the assign keys to off. To do this
simply press the ones that are illuminated which will then toggle
them off. Then press the SET keys on the channel that need no
assignment.