Console Memory Storage to Another Media.
The internal console memory can be stored either by a MIDI SYSEX dump or RS-232 down load to the Klark
Teknik Utilities program Lsutils (this will require a Null Modem Cable).
MIDI Sysex Dumps:
To store and recall the memory of a console to and from a MIDI device (such as an MDF3 MIDI Filer) or the
windows software application available from Midas .
1/ Select the SYSTEM menu, using the UP and DOWN switches select DATA and press CONFIRM.
2/ Using the UP/DOWN keys select either SAVE or LOAD and press CONFIRM.
3/ There are 2 ways of communication either MIDI (through the MIDI port in the rear of the console or via
RS-232). Select either MIDI or SERIAL using the UP and DOWN switches and press CONFIRM. The
display will then indicate the function being carried out and notify the user when finished.
Saving The Memory From The L3000 To A File:
1/ Connect the null modem cable.
2/ On the computer select the SHOW menu and click on 'Download From Console'. A window will open and
set up the Comm Port. The message WAITING FOR SHOW data will then be displayed.
3/ Select the 'SYSTEM' menu on the L3000 and scroll to 'DATA'. Press 'CONFIRM', then scroll to 'SAVE'
and press 'CONFIRM'. Now scroll to 'RS232' and press 'CONFIRM'.The show memory from the L3000
will then be down loaded into the computer. When the data transfer is complete, the L3000 will ask you to
confirm the STORE, press CONFIRM.
4/ Select the Show menu in Hsutil and click on 'Save To File'.
5/ A prompt will appear asking for a show a name. Give the file type as *.shw.
6/ Click on OK and the file will be saved.
Down Loading A Show Into The L3000:
1/ Connect the null modem cable.
2/ On the computer select SHOW menu and click on 'Load From File'. Using the browse function select the
show you wish to download into the console and click on OK. A window will open telling you the loading is
complete, click on OK.
3/ Select the Show menu in Hsutil and click on 'Upload To Console'. A window will open asking you to hit
upload when console is ready.
4/ Select the SYSTEM menu on the L3000, and scroll to 'DATA' then press 'CONFIRM'. Scroll to 'LOAD' and
press 'CONFIRM'. Now scroll to RS-232 and press 'CONFIRM'.
5/ Click on the 'Upload' button.
6/ When the file is uploaded successfully, the L3000 will prompt you to press CONFIRM. The show memory
from the computer will now be loaded into the L3000.