The FOH MUTE switch mutes the front
of house stereo effects return signal path
at all points. The switch can be controlled
from snapshot automation.
The SOLO switch sends stereo effects
return monitor channel signals to the
MON PFL/AFL busses and sends front
of house stereo effects return signals to
the FOH PFL/AFL stereo busses. If the
switch is pressed for a short time it will
latch on or off, but, if it is held on for
more than 1 second the latching is
disabled and when the switch is released
the channel solo will turn off. As a
default the solo system is auto cancelling
so each new solo cancels the last. The
SOLO ADD mode switch on the master
module defeats the auto cancelling and
allows multiple channel monitoring.
The FOH FADERS give independent
adjustment of the front of house stereo
effects return levels from + 10dB to off.
MUTE
l
r
PAN
SOLO
MONO
ST
10
1
5
2
3
0
4
5
5
6
10
7
20
8
f.o.h
30
40
SET
50
dB
s.e.r. 1
23
The PAN defaults to control the channel
placement within the master stereo mix
and has a constant power law. i.e. - 3dB
at the centre position.
The PAN switch changes all group bus
assignments to operate via the stereo pan
pot.
The MONO switch connects the post
fader stereo effects return signal to the
mono master bus.
The ST switch connects the post fader
stereo effects return signal to the master
stereo bus via the pan control.
The SET switch is used to programme
the stereo effects return audio group
assignment. The central controller
MODE switches and ASSIGN keys
select the desired audio group and the
SET switch toggles the stereo effects
return on and off the bus with each
alternate press.