Conversion to LP gas

Check in the 'Technical Data' section at the back of the
instructions that the cooker is convertible to the gas you
want to use.
This conversion must be performed by a competent person,
in accordance with these instructions and with the local
supply company requirements.
Failure to convert the appliance correctly could invalidate any
warranty or liability claims and lead to prosecution.
Th conversion instructions must be used in conjunction
with the rest of the appliance instruction, in particular for
information on Standards, cooker positioning, connection,
hose suitability etc.
When servicing or replacing gas-carrying components,
disconnect from the gas before starting, and check that the
appliance is gas sound after completion.
Do not use reconditioned or unauthorised gas controls.
Disconnect from the electricity supply before commencing
servicing. Before electrical reconnection, check that the
appliance is electrically safe.
Injectors
Standard burner
ArtNo.311-0010 Injectors
A - Jet, B - Internal injector, C - External injector
Remove burner caps and heads. Remove old jets. Fit the new
jets (see Technical Data section at the back of the book for
correct jets). Reassemble in reverse order.
Tap Adjustment
Disconnect from the electricity supply.
Pull off all the control knobs.
Open the grill and right hand oven doors and remove the 4
fixing screws underneath the control panel.
The control panel should drop down slightly. It is held at
the top by two holes on the top edge, one at each end, that
locate onto tags on the inner panel.
Check the appliance is electrically safe and gas sound when you have finished.
Wok burner (some models only)
INSTALLATION
Clear the holes from the inner panel and pull the control
panel forward:
1
Take care not to damage or strain the wiring.
To convert to LP gas
Turn the bypass screw on each control clockwise to the stop:
Tap bypass screw
Refit the control panel. Locate the holes on the top edge onto
the tags on the inner panel, and replace the fixing screws in
the bottom edge.
Affix Label
Stick the LP gas label over the natural gas part of the
appliance data label.
Pressure Testing
Ensure that the appliance is gas sound (refer to
'Pressure Testing' earlier in the section).
Check the operation of all the burners.
21
2
ArtNo.311-0011 Fitting the top panel
ArtNo.311-0012 Tap bypass screw