Opticon NFT 2100 User Manual

Opticon NFT 2100 User Manual

Miniature high speed ccd fixed position barcode scanner
Table of Contents

Advertisement

Quick Links

NFT 2100
Miniature High Speed CCD
Fixed Position Barcode Scanner
User's Guide
Manual No. 25-ULNFT2100-01

Advertisement

Table of Contents
loading

Summary of Contents for Opticon NFT 2100

  • Page 1 NFT 2100 Miniature High Speed CCD Fixed Position Barcode Scanner User’s Guide Manual No. 25-ULNFT2100-01...
  • Page 2: Table Of Contents

    Common Causes of Poor Performance Modified and/or Customized Scanners Section 6 Scanner Labeling Section 7 Scanner Servicing and Maintenance Appendix A How to Program the Scanner Appendix B Computer Programming Commands Appendix C Bar Code Programming Commands Appendix D Dimensional Drawings...
  • Page 3: Section 1 Introduction And Getting Started

    This manual provides the necessary instructions for installing and using the Opticon NFT 2100 Fixed Position Scanner. The manual is organized as follows: Section 1 Introduction and Getting Started Describes the general operation of the NFT 2100 scanner. Also provides a Quick Start- Up Procedure that allows you to begin using the scanner immediately.
  • Page 4: Section 1 Introduction And Getting Started

    Introduction and Getting Started Product Overview The NFT 2100 Fixed Position Scanner is a miniature, 200 scan per second, CCD barcode reader designed to be easily incorporated into host equipment. The small physical size makes the scanner easy to integrate into any hardware design. Durability and reliability are assured.
  • Page 5 3) A red LED light should be visible. If it is not visible, the scanner may be in a mode that requires a “Trigger” Command from the PC to activate it. You can exit that mode by sending the following command from your PC keyboard: <Esc>...
  • Page 6: Section 2 Technical Specifications

    Focal Distance * Field size at focal distance. Narrow Bar Resolution Minimum PCS Reading Distances NFT 2100. See Appendix E) * measured from front edge of scanner. NFT 2100 CCD Fixed Mount Barcode (2000 mm) 200 scans per second ±10%...
  • Page 7: Pitch

    Manual No. 25-ULNFT2100-01; Mar, 2005 NFT 2100 CCD Fixed Mount Barcode Scanner Skew α α Aviod this region ±30º ±10º Specified operation (α) at + 30º or less. (Recommended at + or - 13º) Avoid specular reflection in the dead zone (±10º).
  • Page 8: Tilt (Rotation)

    Manual No. 25-ULNFT2100-01; Mar, 2005 NFT 2100 CCD Fixed Mount Barcode Scanner Tilt (Rotation) φ ±10º Specified operation (θ) ±10º or less. (Barcode aspect ratio must allow the field of view to cover all bars). (Recommended operation at 0º) Curvature EAN-8 / UPC-E: R = >20 mm (0.8”) or...
  • Page 9: Electrical Specification

    RS232 Receive Data Format, Command inputs to scanner. First to last Format RS232 Signal Level Signal Name NFT 2100 CCD Fixed Mount Barcode Optional Settings 1 or 2 bits 7 or 8 bits Odd / Even / None 150 to 38,400 baud...
  • Page 10: Connector Pin Outs

    The kit includes: Scanner 5V Power Supply (32-00907-01) User Manual CD ROM (including manual, datasheet and supporting materials) Regulatory EN55022, EN55024 Class B NFT 2100 CCD Fixed Mount Barcode Direction Power Plug/Jack Output Center Input Rear...
  • Page 11: Section 3 Positioning The Scanner

    It is the distance from the left edge of the view to the right edge. For the NFT 2100, the FOV will be 3.1" at its focal distance of 1.4". Any part of a bar code label that is positioned outside of the FOV will make the label unreadable.
  • Page 12 3) Avoiding Specular Reflection Do not position the scanner at an angle that causes the LED light to be reflected directly back into the scanner. This is called specular reflection. Too much reflected light can “blind” the scanner preventing a good decode.
  • Page 13: Measuring Scanner Performance

    Since the buzzer sounds each time the bar code is read, the sound of the buzzer can be used like a “Geiger counter”. As the position of the scanner changes the sound of the buzzer will change. The buzzer sound will be loudest and most continuous at the best reading position.
  • Page 14: Tips For Verifying The Presence Of A Bar Code

    Your Opticon scanner, when operated in the Trigger Enabled mode, can be programmed to transmit an error message indicating whether or not a bar code was present. See Section 33 of Appendix C of this manual for details.
  • Page 15: Section 4 Configuring The Scanner

    Scanner Section 4 Configuring the Scanner Since the operation of the NFT 2100 scanners are microprocessor controlled, it is possible to modify or program its operation to match your specific application. Changes in parameter settings can be accomplished two ways.
  • Page 16: Section 5 Application Engineering Support

    Application Engineering Support Technical Assistance and Support Opticon is eager to help you integrate the NFT 2100 scanner into your application. Our technical support staff is available to answer any questions or work with you to adapt the scanner to your specific situation.
  • Page 17: Section 6 Scanner Labeling

    Scanner Labeling IEC 825-1 Class 1 LED Devices The NFT 2100 has been examined and found to be a CE Class 1 LED Device according to the relevant requirements of IEC 825-1 and corresponding EN 60825-1 (1993-11) including amendment 1 (1997-09) and amendment 2 (2001-01).
  • Page 18: Appendix A How To Program The Scanner

    Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner Appendices Appendix A How to Program the Scanner Appendix B Computer Programming Commands Appendix C Bar Code Programming Commands Appendix D Dimensional Drawing Appendix E Optical Performance (typical) NFT 2100 CCD Fixed Mount Barcode Page 15...
  • Page 19 While in this mode the scanner will beep intermittently. 2. Scan the bar code(s) associated with the desired parameter(s). The scanner will beep when the bar code is read. Note: because of the close proximity of bar codes on the page, it is important to aim carefully to ensure that only the desired bar code is scanned.
  • Page 20 NFT 2100 CCD Fixed Mount Barcode Scanner When the scanner is in the Programming Mode, you can change more than one parameter at a time. However, this may become confusing. Until you become proficient at programming you may prefer to change only a few parameters at one time.
  • Page 21: Appendix B Computer Programming Commands

    EAN (13/8) +2 EAN (13/8) +5 2 or 5 Industrial 2 or 5 Interleaved TriOptic SCode NFT 2100 CCD Fixed Mount Barcode Enable Disable Options for UPC-A and UPC-E UPC-A as EAN13 (13 Digits) Transmit leading zero & CD UPC-A (12 Digits) No leading zero...
  • Page 22 Enable 1 character minimum Enable 3 characters minimum Enable 5 characters minimum Transmit S-Code as I 2 of 5 Primary/Alternative Algorithm NFT 2100 CCD Fixed Mount Barcode Enable Disable Options for IATA Do not calculate check digit Calculate CD (CPN + Form +...
  • Page 23 Direct Input ASCII Control Characters Cmd. Char. Cmd. Char. null Direct Input Miscellaneous Characters Cmd. Char. Cmd. Char. NFT 2100 CCD Fixed Mount Barcode Direct Input Miscellaneous Characters <SPAC Communication Parameters 150 baud 300 baud Char. 600 baud 1,200 baud thru thru...
  • Page 24 Activate the trigger; turns the LEDs ON Terminate the trigger. Selecting the Read Mode Single Read Mode (Trigger must be Enabled, NFT 2100 CCD Fixed Mount Barcode Multiple Read Mode Continuous Read Mode Scanner Timeout (Trigger Mode) 1 second after triggering...
  • Page 25 No response to command Response to command – OK=ACK, ERROR=NAK Good Read LED Operation NFT 2100 CCD Fixed Mount Barcode Disable good read LED (GRL) GRL ON for 0.20 seconds after decode GRL ON for 0.40 seconds after decode GRL ON for 0.80 seconds after decode...
  • Page 26: Appendix C Bar Code Programming Commands

    30. Quiet Zone Options ... 61 31. Redundant Decoding... 62 32. Transmitting Error Indications (Trigger Enabled only) ... 62 33. Programming No Read Error Messages ... 63 34. Good Read LED Operation ... 63 NFT 2100 CCD Fixed Mount Barcode Page 23...
  • Page 27: Global Default & Scanner Configurations

    Note: Where computer commands appear in parenthesis, bar code commands must be used to start and end manual programming of the scanner. Note: Scanner default settings are indicated by a pointing hand ( ) symbol throughout the menus to follow.
  • Page 28: Symbology Selection

    Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 2. Symbology Selection Computer Command (ZZ) Only Code-128 (Inc. EAN-128) NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu Enable all bar code symbologies Enable all UPC and EAN Only Code-39 Only Codabar (NW-7)
  • Page 29 Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 2. Symbology Selection (continued) Computer Command (ZZ) NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu Only EAN (13/8) Only EAN (13/8) +2 Only EAN (13/8) +5 Only Industrial 2 of 5...
  • Page 30: Add/Activate Specific Bar Code Symbologies

    Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 3. Add/Activate Specific Bar Code Symbologies Computer Command (ZZ) NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu Enable Code 39 Enable Codabar (NW-7) Enable IATA Enable Code 93 Enable Code 128...
  • Page 31: Delete/Deactivate Bar Code Symbologies

    Computer Command (ZZ) START/END Programming Menu Enable Interleaved 2 of 5 4. Delete/Deactivate Bar Code Symbologies Computer Command (ZZ) NFT 2100 CCD Fixed Mount Barcode Function /Description Enable EAN (13/8) +5 Enable Industrial 2 of 5 TriOptic SCode Function /Description...
  • Page 32: Options For Upc

    UPC-E (7 Digits) Do not transmit first character, do transmit check Do transmit first character, do Do not transmit first character Do not expand UPC-E to UPC-A NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu Transmit check digit...
  • Page 33: Options For Ean-8 & Ean-13

    Scanner 6. Options for EAN-8 & EAN-13 Computer Command (ZZ) EAN-13 Do not transmit CD EAN-8 Do not transmit CD NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu EAN-13 Transmit CD EAN-8 Transmit CD Disable ISBN translation...
  • Page 34: Options For Code-39 & It Pharmaceutical)

    Do not transmit check digit Do not transmit start/stop Transmit start/stop characters algorithms for Code 39, I & D 2 Alternate decode algorithm no.1 Alternate decode algorithm no.2 NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu Enable 3 characters Transmit check digit characters (*……*)
  • Page 35: Options For Codabar (Nw-7)

    8. Options for Codabar (NW-7) Computer Command (ZZ) Enable 1 character (3 characters including start/stop characters) characters as ABCD/TN*E characters as ABCD/ABCD NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu enable code 39 disable code 39 possible...
  • Page 36 Enable normal, ABC & CX Disable ABC & Cx Codabar Disable Inter-character Gap Enable Inter-character Gap algorithms for Code 39, I & D 2 Alternate decode algorithm for NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu Transmit start/stop...
  • Page 37 • optional and, if present, would be the last character before the stop character. If the scanner is programmed to calculate the check digit and the bar code is not printed with a • check digit, the bar code will not be read.
  • Page 38: Options For 2 Of 5 (Including Scode)

    Alternate algorithm for I 2 of 5, 2 of 5 Format (Standard (Industrial) and Interleaved) Opticon strongly recommends that the “Setting the Number of Digits” featured in Section 13 be employed whenever 2 of 5 bar codes are used. NFT 2100 CCD Fixed Mount Barcode...
  • Page 39: Options For Iata

    ♦ Selection of the check digit calculation ♦ Disable transmission of the check digit Check digit calculation: If the check digit calculation is required, then the appropriate calculation method must be selected. NFT 2100 CCD Fixed Mount Barcode Function /Description START/END...
  • Page 40: Options For Code-128 & Ean-128

    Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 11. Options for Code-128 / EAN-128 Computer Command (ZZ) 12. Options for Code-93 Computer Command (ZZ) NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu Disable EAN-128 only Enable EAN-128 only Disable concatenation Enable concatenation Function...
  • Page 41: Setting The Number Of Digits

    To avoid truncation errors, the scanner can be programmed to only decode bar codes of one specific length, i.e., containing a specific number of digits. It is also possible to program the scanner to only decode bar codes of either of two specific lengths.
  • Page 42: Creating A Prefix And/Or Suffix

    Prefix/Suffix value and length (expressed in hexidecimal The Z3 command can be used to instruct the scanner to provide a list of its current software settings including prefixes and suffixes. The scanner can be programmed to transmit a prefix and/or suffix with the decoded data. A Prefix (or a Suffix) is composed of up to 4 characters.
  • Page 43 8. Scan N1, representing a Prefix for UPC-A 9. Scan 0A, representing the alpha character “A” 10. Scan N6, representing a Suffix for UPC-A 11. Scan 0B, representing the alpha character “B” 12. Scan “START/END Programming Mode” NFT 2100 CCD Fixed Mount Barcode Page 40...
  • Page 44: Setting Prefixes (Identifying The Symbology)

    Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 15. Setting Prefixes (Identifying the Symbology) Computer Command (ZZ) NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu All codes UPC-A UPC-A +2 or +5 UPC-E UPC-E +2 or +5 EAN-13 EAN –13 +2 or +5...
  • Page 45 Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 15. Setting Prefixes (Identifying the Symbology) (continued) Computer Command (ZZ) NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu Interleaved 2 of 5 Code 93 Code 128 IATA MSI/Plessey SCode Telepen Preamble (all codes)
  • Page 46: Setting Suffixes (Identifying The Symbology)

    Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 16. Setting Suffixes (Identifying the Symbology) Computer Command (ZZ) NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu All Codes UPC-A UPC-A +2 or +5 UPC-E UPC-E +2 or +5 EAN-13 EAN–13 +2 or +5...
  • Page 47 Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 16. Setting Suffixes (Identifying the Symbology) (continued) Computer Command (ZZ) NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu Interleaved 2 of 5 Code 93 Code 128 IATA MSI/Plessey SCode Telepen Postamble (All Codes)
  • Page 48: Direct Input Of Numeric Characters

    Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 17. Direct Input of Numeric Characters Computer Command (ZZ) NFT 2100 CCD Fixed Mount Barcode Function Bar Code /Description Command START/END Programming Menu Page 45...
  • Page 49: Direct Input Of Alpha Characters

    Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 18. Direct Input of Alpha Characters START/END (ZZ) Program Menu NFT 2100 CCD Fixed Mount Barcode START/END (ZZ) Program Menu Page 46...
  • Page 50: Direct Input Of Alpha Characters (Lower Case)

    Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 19. Direct Input of Alpha Characters (Lower Case) START/END (ZZ) Program Menu NFT 2100 CCD Fixed Mount Barcode START/END (ZZ) Program Menu Page 47...
  • Page 51: Direct Input Of Control Characters

    START/END (ZZ) Program Menu (null) (SCH) (STX) (ETX) (EOT) (ENQ (ACK) (BEL) (BS) (HT) (LF) (VT) (FF) NFT 2100 CCD Fixed Mount Barcode (CR) (SO) (SI) (DLE) (DC1) (DC2) (DC3) (DC4) (NAK) (SYN) (ETB) (CAN) (EM) START/END (ZZ) Program Menu...
  • Page 52 Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 20. Direct Input of Control Characters (Continued) Computer Command (ZZ) NFT 2100 CCD Fixed Mount Barcode Function Bar Code /Description Command START/END Programming Menu ^Z (SUB) ^[ (ESC) ^\ (FS) ^] (GS) ^^ (RS)
  • Page 53: Direct Input Characters Miscellaneous

    Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 21. Direct Input Characters Misc. START/END (ZZ) Program Menu (SPACE) “ & NFT 2100 CCD Fixed Mount Barcode < > START/END (ZZ) Program Menu CONTINUED ON NEXT PAGE... Page 50...
  • Page 54 Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 21. Direct Input Characters Misc. (Continued) Computer Command (ZZ) NFT 2100 CCD Fixed Mount Barcode Function Bar Code /Description Command START/END Programming Menu ‘ Page 51...
  • Page 55: Communication Parameters

    Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 22. Communication Parameters Computer Command (ZZ) NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu 150 baud 300 Baud 600 Baud 1,200 Baud 2,400 Baud 4,800 Baud 9,600 Baud 19,200 Baud 7 Data Bits...
  • Page 56: Handshaking

    Command (ZZ) Unlimited wait for CTS from 100 mS wait for CTS from 200 mS wait for CTS from 400 mS for CTS from terminal NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu 1 Stop Bit 2 Stop Bits...
  • Page 57 Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner 23. Communication Delays ACK/NAK no response (100 ms timeout, terminates with good 20 ms intercharacter delay 50 ms intercharacter delay 100 ms intercharacter delay NFT 2100 CCD Fixed Mount Barcode read buzzer) No intercharacter delay Page 54...
  • Page 58: Buzzer Operation

    Volume = Upper Mid-range Volume = Lower Mid-range Buzzer duration 0.10 sec Buzzer duration 0.20 sec Buzzer duration 0.40 sec Buzzer duration 0.05 sec NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu Volume = Maximum Volume = Minimum...
  • Page 59: Setting The Trigger Functions

    Continuous Read Mode. (will read the same label over and The operation of the scanner in the various read modes is described in the table below. The “Continuous Read” mode is helpful in positioning the scanner for optimum reading. In “Continuous Read,” the scanner’s buzzer functions like a Geiger counter, sounding the most active at the position achieving the...
  • Page 60 The Read scanner time out is terminated on a (S0) NFT 2100 CCD Fixed Mount Barcode Trigger Function Disabled (S7) Scanner will read different bar codes in succession if they are presented to Scanner may not read the same bar code twice if they are consecutive.
  • Page 61: Add-On Wait Mode

    If a valid add-on code is found, the reader transmits the data immediately. If nothing is found behind the code, the reader will transmit the data without the add-on. NFT 2100 CCD Fixed Mount Barcode Function...
  • Page 62: Scanner Timeout (Trigger Enabled Mode Only)

    On time follows the Hardware trigger active time. Can be terminated by sending the Y Stays ON indefinitely after triggering. Must be terminated by sending the Y commands. NFT 2100 CCD Fixed Mount Barcode Function /Description START/END Programming Menu Read time x 10...
  • Page 63: Multiple Read Reset Time

    This option is used in conjunction with the multiple read mode. The selected time sets the period the scanners should be pointed away from a label before that same label can be decoded again. Indefinitely means that the next bar code must always be different during the time the scanner is triggered. Computer...
  • Page 64: Quiet Zone Options

    30. Quiet Zone Options With this option the scanner can decode bar codes that have smaller quiet zone margins than specified for the symbology. Be careful when using this option as its use may increase the possibility of partial and ghost reads.
  • Page 65: Redundant Decoding

    In the case of a poor label which generates an intermediate “no decode” within a sequence of four scans where three of the four have resulted in “good reads”, the scanner will transmit the data after the fourth scan. In other words, a “no decode” does not restart the sequence.
  • Page 66: Programming No Read Error Messages

    33. No read error messages. The scanner can be programmed to transmit an error message when no barcode is read. The unit must be in trigger mode, then, the error message will be sent at the end of a trigger time out. 2 types of messages can be sent.
  • Page 67: Appendix D Dimensional Drawings

    Manual No. 25-ULNFT2100-01; Mar, 2005 NFT 2100 CCD Fixed Mount Barcode Scanner Appendix D: Dimensional Drawing (All dimensions in millimeters [inches]) Page 64...
  • Page 68: Appendix E Optical Performance (Typical)

    Manual No. 25-ULNFT2100-01; Mar, 2005 Scanner Appendix E: NFT 2100 – Optical Performance NFT 2100 Depth of Field Table (Grade A Labels) Min. Distance Density (inches) 6 mil 10 mil 20 mil 40 mil NFT 2100 Depth of Field Chart Focal Distance 1.4"...
  • Page 69: Appendix F Placement Drawings

    Placement Drawing (All dimensions in millimeters [inches]) This Drawing shows one possible placement of the scanner relative to the target label. Other orientations are possible depending on barcode density and barcode length. Please use the optical information provided in appendix E as guidance.
  • Page 70: Appendix G Placement Drawings For Test Tubes

    Placement Drawing for test tubes (All dimensions in millimeters [inches]) This Drawing shows one possible placement of the scanner relative to the target label. Other orientations are possible depending on barcode density and barcode length. Please use the optical information provided in appendix E as guidance.
  • Page 71 Manual No. 25-ULNFT2100-01; Mar, 2005 NFT 2100 CCD Fixed Mount Barcode Scanner Notes Page 68...

Table of Contents