L. Input isolation
M. Shipping Details

2-2. Operating specifications

A. Performance
- Accuracy
Performance
- Accuracy
Performance
- Accuracy
Performance
- Accuracy
Performance
- NaCl table
- Matrix
- Ambient influence
- Step response
B. Ambient operating temperature
C. Storage temperature
D. Humidity
mA
E. HART specification
- Min. cable diameter : 0.51 mm, 24 AWG
- Max. cable length
Detailed information can be found at: www.hartcomm.org
F. Housing

2-3. Model and suffix codes

Model
Suffix Code Option code Description
SC202G
SC202S
Type
- A
- D
- P
- F
- N
- B
- E
Options
: 1000 VDC
: Package size w x h x d
290 x 225 x 170 mm.
11.5 x 8.9 x 6.7 in.
Packed weight approx. 2.5 kg (5lb).
: Conductivity
: ≤ 0.5 % ± 0.02 mA
: Resistivity
: ≤ 0.5 % ± 0.02 mA
: Temperature with Pt1000Ω,
Ni100Ω and Pb36 NTC
: ≤ 0.3 °C ± 0.02 mA
: Temperature with PT100Ω and
8k55Ω
: ≤ 0.4 °C ± 0.02 mA
: Temperature compensation
: ≤ 1 %
: ≤ 3 %
: ≤ 0.05 %/°C
: 90 % (< 2 decades) in ≤ 7 seconds
: -10 to +55
C (-10 to 130 ºF)
o
Excursions to -30 to +70
C
o
(-20 to 160 ºF) will not damage the
instrument, specification maybe
adversely affected
Drift < 500 ppm/°C
: -30 to +70
C (-20 to 160 ºF)
o
: 10 to 90% RH non-condensing
: 1500 m
: Cast aluminium case with chemically
resistant coating, cover with flexible
polycarbonate window. Case color
is off-white and cover is moss green.
Cable entry is via two
/
" polyamide
1
2
glands. Cable terminals are provided
for up to 2.5 mm
finished wires.
2
Weather resistant to IP65 and NEMA
4X standards. Pipe wall or panel
mounting, using optional hardware.
Conductivity Transmitter, General Purpose version
Conductivity Transmitter, Intrinsic Safe version
Milli-amp (+HART) version
Non incendive profibus PA version
profibus PA version
FOUNDATION ® Fieldbus version
Non-Incendive Milli-amp (+HART) version
Non-Incendive FOUNDATION ® Fieldbus version
Always E
/H
Hood for Sun Protection
/U
Pipe & Wall mounting hardware
/SCT
Stainless steel tagplate
/Q
Calibration certificate
G. Data protection
: EEPROM for configuration and
logbook, and lithium battery for clock.
H. Watchdog timer
: Checks microprocessor
I.
Automatic safeguard : Return to measuring mode when no
J. Operation protection : 3-digit programmable password.
K Regulatory compliance
- EMC
: meets council directive 89/336/EEC
- Emmission
: meets EN 55022 Class A
- Immunity
: meets EN 61000-6-2
L) Intrinsic safety
- ATEX
: EEx ib [ia] IIC T4 for Ta -10 to 55 ºC
EEx ib [ia] IIC T6 for Ta -10 to 40 ºC
II 2 (1) G
KEMA 00ATEX1069 X
- CSA
: Ex ia CL I, DIV 1, GP ABCD,
T4 for Ta -10 to 55 ºC
T6 for Ta -10 to 40 ºC
Refer to Installation Drawing
SC202S CSA
- FM
: IS CL I, DIV 1, GP ABCD
T4 for Ta -10 to 55 ºC
T6 for Ta -10 to 40 ºC
HAZ LOC per Control Drawing
FF1-SC202S-00
M) Non-Incendive
- FM
: NI CL I, DIV 2, GP ABCD
T4 for Ta -10 to 55 ºC
T6 for Ta -10 to 40 ºC
HAZ LOC per Control Drawing
FF1-SC202S-00
- CSA
: NI CL I, DIV 2, GP ABCD
T4 for Ta -10 to 55 ºC
T6 for Ta -10 to 40 ºC
Refer to Installation Drawing
SC202S CSA
- ATEX
: EEx nA [L] IIC T4 for Ta -10 to 55 ºC
EEx nA [L] IIC T6 for Ta -10 to 40 ºC
II 3 G
KEMA 00ATEX1070 X
N. DD specification
: The SC202 Device Description
is available enabling communications
with the Handheld Communicator
Specifications 2-2
keystroke is made for 10 min.
(HCC) and compatible devices.
IM 12D7B3-E-E