5.0 SR-100P INSTALLATION

Prior to installing the SR-100P, be sure to review the general installation procedures given
above. Note the default rate for the SR-100P camera is 19200 baud.
The SR-100P camera utilizes a 16-pin jam nut, panel-mount receptacle (Souriau 85107E2016P)
as the power and serial input connector, and an MS-type mating connector (Souriau
85106EC2016S) is supplied with the camera. The leads are first connected to the mating
connector and the mating connector is then inserted into the receptacle on the rear of the
camera.
On the SR-100P camera, the shielding and Earth grounding are critical parts of the interface
cable construction. Both are required in order to control radio frequency emissions and protect
from high energy outdoor events such as the indirect effects of lightning.
The following cable example shows two ground connection points. Both ground leads are
internally connected to all of the shields of the cabling and terminated externally with lugs. One
terminal lug (white lead in this example) is to be connected to the connector shell and the other
(green with yellow stripe) is to be connected to the Earth connection point on the rear of the
camera system. The Earth connection point is then required to be connected to Earth Ground.
427-0014-00-10 Revision 210

Figure 5-1: SR-100P with Sun Shroud

Cable shields from all cables (video, power,
serial) are joined and connected to two ground
leads (white and green) with terminal lugs.
Attach one ground here, as shown, and also
attach the Earth Ground connection here (not
shown).
The other ground should be attached to the
connector shell, as shown here.
Copyright © 2008 FLIR Systems, Inc.