Table of Contents

Advertisement

Quick Links

T
h
e
T
h
e
I
n
s
t
a
l
l
a
t
I
n
s
t
a
l
l
a
t
ThermalVideo.com
Your Source for Modern Thermal Imaging Systems
P.O. BOX 4242
Middletown, NY 10941
PH: + 1 888 919 2263
PH Intl: + 1 845 343 4077
FX: + 1 845 343 4299
support@thermalvideo.com
427-0014-00-10 Revision 150
S
R
-
S
S
R
-
S
r
m
a
l
r
m
a
l
i
o
n
a
n
d
O
i
o
n
a
n
d
O
e
r
i
e
s
e
r
i
e
s
C
a
m
e
C
a
m
p
e
r
a
t
i
o
n
p
e
r
a
t
i
o
n
Copyright © 2007 FLIR Systems, Inc.
r
a
e
r
a
M
a
n
u
a
l
M
a
n
u
a
l
Camera
Models:
SR-100
SR-100P
SR-50
SR-35
SR-19
VSR-6
January 2008
w w w.thermalvideo.com
1

Advertisement

Table of Contents
loading

Summary of Contents for FLIR SR-Series

  • Page 1 Camera Models: SR-100 SR-100P SR-50 SR-35 SR-19 VSR-6 January 2008 ThermalVideo.com Your Source for Modern Thermal Imaging Systems w w w.thermalvideo.com P.O. BOX 4242 Middletown, NY 10941 PH: + 1 888 919 2263 PH Intl: + 1 845 343 4077 FX: + 1 845 343 4299 support@thermalvideo.com 427-0014-00-10 Revision 150...
  • Page 2 ThermalVideo.com PO BOX 4242 Middletow, NY 10940 Toll Free: 1-888-919-2263 Intl.: +1-845-343-4077 Fax: 1-845-343-4299 www.thermalvideo.com Number: 427-0014-00-10 Number: January 2008 EXPORT RESTRICTIONS The information contained in this document may be controlled for export purposes by the United States Government. Diversion contrary to US law is prohibited. For more information, contact FLIR Systems, Inc.
  • Page 3: Table Of Contents

    Thermal Imaging....................23 Configuration and Control................. 23 Pelco Keyboard Control..................24 Flat Field Correction (FFC) ................24 8.0 CARING FOR YOUR SR-SERIES THERMAL CAMERA ......25 Temperature ..................... 25 Maintenance ..................... 25 Troubleshooting Problems................26 9.0 SR-SERIES CAMERA SPECIFICATIONS..........28 SR-Series Camera Dimensions................
  • Page 4: Figure 1: Thermal Image From Sr-Series Camera

    Figure 13: Mating connector as seen from end of cable.............18 Figure 14: Front view of SR-Series camera ................20 Figure 15: SR-Series Connections (VSR-6, SR-19, SR-35, and SR-50) ........21 Figure 16: Tongue and Groove Alignment..................22 Figure 17: Camera Side View .....................29 Figure 18: Camera Rear View ....................29...
  • Page 5: Warnings And Cautions

    If you have questions that are not covered in this manual, or need service, contact FLIR Customer Support at (805) 964-9797 for additional information prior to returning your SR-Series Thermal Camera. In the US, you can also reach FLIR Customer Support at (888) 747-FLIR (747-3547).
  • Page 6: Introduction

    Unlike other night vision systems that require low amounts of light to generate an image, the SR-Series thermal imagers need no light at all. The cameras are available with a choice of lenses for short-, medium- and long-range surveillance capability.
  • Page 7: Advantages Of Thermal Imaging

    20° and is well-suited for short range threat detection in all circumstances. SR-19 The SR-19 camera features a focal length of 19mm (36° HFOV) and, like the other SR-series cameras, has a standard resolution Focal Plane Array (FPA) with 320 (H) x 240(V) pixels. It gives you an extremely wide field of view, so that you can cover a large area and keep excellent situational awareness.
  • Page 8: Serial Remote Control

    The SR-Series is designed to be a drop-in replacement for current systems employing daylight cameras. Initial setup of the system includes connecting power supply leads for the input power and a BNC cable for monitoring output video.
  • Page 9: Camera Enclosures

    Figure 4: White Hot palette on left, Black Hot palette on right 2.3 Camera Enclosures SR-Series cameras are packaged in environmental enclosures that meet IPX6 test standards. Refer to section 0 SR-Series Camera Specifications for additional information. The camera’s sun shroud around the enclosure helps regulate the camera temperature in direct-sun installations.
  • Page 10: Package Contents

    Figure 6: SR-100P with Sun Shroud 2.4 Package Contents Refer to the Shipping Check List that is shipped with each camera for a description of the parts and components that are included with the camera. If there is any discrepancy between the list and the contents of your shipment, please contact FLIR Systems Customer Support immediately using the contact information at the front of this manual.
  • Page 11: Installation

    SR-100P Installation VSR-6, SR-19, SR35, SR-50 Installation If you have a question regarding installation or operation of your SR-Series camera, contact FLIR Systems, Inc Customer Support, using the contact information at the front of this manual. Check out our training web site (http://www.flir.com/training/) to get information on courses offered and to learn how you can become a FLIR-authorized Installer.
  • Page 12: Ground Connection

    Installation). No disassembly is required for the SR-100P pressurized camera. The SR-Series provides electrical contacts in the form of screw-terminal jacks, allowing it to receive 10-28 AWG tinned leads from the power supply and serial communication interface. 3.2 Ground Connection...
  • Page 13: Input Power

    3.3 Input Power The SR-Series cameras operate on either 24VDC or 24VAC power (nominal). Refer to section 0 SR-Series Camera Specifications for additional power requirements. The cameras provide screw-terminals for receiving tinned leads for input power. For details on how to connect the leads, refer to the installation section for each specific camera below.
  • Page 14: Analog Video Output

    3.6 Camera Mounting Mounting the SR-Series camera is accomplished using the ¼x20 tripod mount holes on the underside of the enclosure foot. FLIR Systems recommends using the supplied hardware. The dimensions of the camera mounting foot are provided in section 0...
  • Page 15: Sr-100 Installation

    4.0 SR-100 INSTALLATION Prior to installing the SR-100, be sure to review the general installation procedures given above. In particular, be sure to review section 3.2 Ground Connection. The SR-100 camera provides a removable screw-terminal connector for receiving tinned leads for input power and serial communication leads.
  • Page 16: Figure 10: Screw Terminal Connector

    2. Route the cable with power/ground and serial leads through the left-hand gland on the rear enclosure cover (as viewed from the rear of the enclosure). 3. Connect the two power leads according to Table 1: SR-100 Screw Terminals. Connect the shield of the power cable to the Internal Earth Ground Connection as indicated in the figure above.
  • Page 17: Sr-100P Installation

    5.0 SR-100P INSTALLATION Prior to installing the SR-100P, be sure to review the general installation procedures given above. The SR-100P camera utilizes a 16-pin jam nut, panel-mount receptacle (Souriau 85107E2016P) as the power and serial input connector, and an MS-type mating connector (Souriau 85106EC2016S) is supplied with the camera.
  • Page 18: Figure 13: Mating Connector As Seen From End Of Cable

    Pins B, G and J are tied together for proper ground and shield protection. Figure 12: Mating connector as seen from end of cable The following table describes the pin designations for video, power, and communications signals. Signal Name Pin Designation Comment VID OUT Center (core) of coax video...
  • Page 19: Figure 12: Sr-100P Enclosure Rear

    Figure 13: SR-100P Enclosure Rear 427-0014-00-10 Revision 150 Copyright © 2007 FLIR Systems, Inc.
  • Page 20: Vsr-6, Sr-19, Sr35, Sr-50 Installation

    6.0 VSR-6, SR-19, SR35, SR-50 INSTALLATION Prior to installing the SR-Series camera, be sure to review the general installation procedures given above. The VSR-6, SR-19, SR-35, and SR-50 camera systems each have a fixed-focus lens (focused at infinity at the factory) and the lens focus is not field adjustable.
  • Page 21: Figure 15: Sr-Series Connections (Vsr-6, Sr-19, Sr-35, And Sr-50)

    Ground lug Figure 15: SR-Series Connections (VSR-6, SR-19, SR-35, and SR-50) 2. Route the RG-59 video cable through the right-hand gland (when viewing from the rear) on the rear enclosure cover and crimp the connector to the end of the cable. Connect the cable to the BNC bulkhead connector.
  • Page 22: Figure 16: Tongue And Groove Alignment

    Bracket Tongue Bracket Tongue Enclosure Groove Enclosure Groove Figure 16: Tongue and Groove Alignment 5. Secure the front cover to the enclosure using the 6-32 hex head screws. 6. If the ground cable inside the enclosure was disconnected, reconnect it to the ground lug on the rear plate of the enclosure.
  • Page 23: Operating The Sr-Series Thermal Camera

    The SR-Series camera is easy to use, but you should take a moment to carefully read this section so you fully understand how to interpret what you are seeing on your display and how to use the controls.
  • Page 24: Pelco Keyboard Control

    The SR-Series may be controlled by a PC running a Windows-based software application. One software application (known as the TVIS-7 PC User Interface Software) is used for the SR-100 and SR-100P cameras. For information on how to use the software, refer to the section 11.0 SR-100 control using TVIS-7 User Interface.
  • Page 25: Caring For Your Sr-Series Thermal Camera

    Doing so can cause permanent damage and will void the warranty. Your SR-series camera images through a lens that is made from material that is transparent to long-wave infrared energy. This lens is designed for the harsh outdoor environment and has a coating for durability, but may require occasional cleaning.
  • Page 26: Troubleshooting Problems

    Image too dark or too light By default the SR-Series cameras use an Automatic Gain Control (AGC) setting that has proven to be superior for most applications, but a particular installation may require an adjustment to the AGC settings. For example, a very cold background (such as the sky) could cause the camera to use a wider range than appropriate.
  • Page 27 Image freezes By design, the camera image will freeze momentarily on a periodic basis during the Flat Field Correction (FFC) cycle. It is possible to change the interval used for FFC; refer to section 7.4 Flat Field Correction (FFC). 427-0014-00-10 Revision 150 Copyright ©...
  • Page 28: Sr-Series Camera Specifications

    9.0 SR-SERIES CAMERA SPECIFICATIONS Feature VSR-6 SR-19 SR-35, SR-100 SR-100P SR-50 FPA size (HxV) 160x120 320x240 320x240 320x240 320x240 Weight 4.6 lbs, 2.1 4.6 lbs, 5.0 lbs, 7.2 lbs, 3.3 11.5 lbs, 5.2 2.1 kg 2.7 kg Dimensions Refer to detailed drawings below in section 9.1...
  • Page 29: Sr-Series Camera Dimensions

    9.1 SR-Series Camera Dimensions Length Figure 17: Camera Side View Width Height Figure 18: Camera Rear View Dimension VSR-6 SR-19 SR-35, SR-100 SR-100P SR-50 Length 10.5” (26.7) 18” (45.7) Width 5.0” (12.7) 4.5” (11.4) Height 5.68” (14.4) 5.5” (13.9) Note: Values in parentheses are in centimeters, all others in inches.
  • Page 30: Figure 19: Enclosure Mounting Foot (All Cameras Except For Sr-100P)

    4.00 (10.08) 2.00 (5.08) 1.00 (2.54) 1.00 (2.54) 2.00 (5.08) Figure 19: Enclosure Mounting Foot (all cameras except for SR-100P) 427-0014-00-10 Revision 150 Copyright © 2007 FLIR Systems, Inc.
  • Page 31: Sr-100P Specifications

    9.2 SR-100P Specifications Ambient Operating -40° to 122°F (-40° to 50°C) with heater(s) Temperature Purge Fitting Standard Schraeder valve to allow enclosure to be filled with dry nitrogen Purge Relief Fitting Prevents over pressurization of enclosure Enclosure Mounting Adjustable cradle secured with stainless steel bands Humidity Up to 100% relative humidity.
  • Page 32: Kbd300 Commands For Use With Sr-100 And Sr-100P

    10.0 KBD300 COMMANDS FOR USE WITH SR-100 AND SR- 100P Note: To start, type the device id (99 is the universal id) and then press CAM Keystrokes TVIS-7 Function Toggle Values (default to first value) Near button Increments Focus closer Note: Holding the Near or Far button down continuously will only move Far button...
  • Page 33: Sr-100 & Sr-100P Control Using Tvis-7 User Interface

    11.0 SR-100 & SR-100P CONTROL USING TVIS-7 USER INTERFACE The SR-100 (formerly known as the TVIS-7º) and the SR-100P may be controlled through various sources including the TVIS-7º User Interface GUI which provides a Windows-based control program (Graphical User Interface) for the SR-100P. Detailed descriptions for using these controls are described in this section.
  • Page 34 2. Manual. In Manual FFC mode, the camera does not perform FFC automatically based on specified values of temperature change or an expired time . EZoom: Electronically multiplies the pixel array by 2, effectively doubling the image size displayed on the monitor. 1X is turned off and 2X is turned on. Region Of Interest (ROI) is used to define the region of the display used to generate the AGC parameters.
  • Page 35 AGC Control TVIS-7º AGC Control AGC TYPE: The AGC or Automatic Gain Control defines the type of function that determines the brightness and contrast of the analog video image. These functions can be non-linear such as the Plateau Equalization or a linear such as in the Linear Histogram and AutoBright selections.
  • Page 36 The Plateau Value specifies a limit to the number of pixels that can be associated with a particular output count value. 2. Linear Histogram algorithm uses scene statistics to set a global gain and offset (contrast and brightness) for the image. This AGC setting linearly adjusts the full 14 bit video bandwidth over the 256 levels of analog video displayed on the monitor.
  • Page 37 Factory Defaults will set the TVIS-7° to factory default settings. Change Pelco Device Address allows for users to define the Pelco Device Address. The device will only accept commands under its new Pelco address or the global address of 99. The TVIS GUI will only communicate using then assigned Pelco address.
  • Page 38 Configuration Control TVIS-7º Configuration Communications Port: The serial communication settings should match those on the PC for communication. The Pelco Address is also displayed. On initial power up, the system will automatically search for the appropriate baud rate. This dialog configures the PC comm. Port that will be used to communicate with the device.
  • Page 39 About Tab TVIS-7º About Screen (Version on Screen not current) The About tab will display the version information and system information. 427-0014-00-10 Revision 150 Copyright © 2007 FLIR Systems, Inc.
  • Page 40: References

    12.0 REFERENCES FLIR Standard Resolution Product Specification Document Number: 427-0014-00-09 FLIR Photon GUI User Guide Document Number 412-0035-00-10 FLIR TVIS 7 Degree Software Interface Control Document (ISC Doc. 427-007-05-21) Pelco EH8100 Series Enclosure Product Specification Pelco EH2500 Series Enclosure Product Specification Pelco Standard TF-002 Pelco “D”...