PLANNING THE INSTALLATION
Recommended
Installation
Instruction
(when
using
BGS-3030
Backguard)
Install
components
in the following
order:
a. Vent Hood
b. gackguard
System
c. Range
1. Locate and [eve[ range according
to Range installation
instructions.
2. Measure distance from floor to top of isHand trim on range adding
]/8" for backguard
cHearance.
3.Transfer this measurement
to the waHL This wH[ mark the bottom
of your backguard.
4. From this [ine measure 28-1/8" up wall[ to mark top of 30" backguard.
This is the minimum
height
that the bottom
of your vent hood can be instaHHed.
5. FoHHow vent hood manufacturer's
instaHHation instructions
to install[ vent hood.
6. Follow backguard
installation
instructions
to install backguard.
7. Connect gas and electric connections
and slide range into position.
VENTILATION
REQUIREMENTS
STEP 1: VENTILATION
REQUIREMENTS
A suitable exhaust
hood must be installed above the range / cooktop.
The following
chart indicates
the minimum
blower capacity recommended
for hood ventilation.
VENTILATION
STANDARD COUNTER
ISLAND
UNIT
INSTALLATION
INSTALLATION
RECOMMENDATIONS
RECOMMENDATIONS
HOOD
(24" Deep x Unit Width)
(30" Deep x 36" at Bottom)-"
BLOWER
600 CFM (rain.)
600 CFM (rain.)
CAUTION:
Ventilation
hoods and blowers are designed for use with single wall ducting.
However, some local building
codes or inspectors
may require double
wall
ducting.
Consult local buiMing
codes and/or local agencies, before starting,
to
ensure that hood and duct installation
will meet local requirements.
Hood blower
speeds should
be variable
to reduce
noise and loss of heated
or air conditioned
household
air when maximum
ventilation
is not required.
For best smoke elimination,
the lower edge of the hood should
be installed
a minimum
of 30" to a
maximum
of 36" above the range cooking
surface (See Fig. 3, page 5).
If the hood contains
any
combustible
materials (i.e.a wood covering)
it must be a minimum
of 36" above the cooking
surface.
Due to a high volume
of ventilation
air, a source of outside
replacement
air is recommended.
This is
particularly
important
for tightly
sealed and insulated
homes.
A reputable
heating
and ventilating
contractor
should be consulted.